background image

Your  Goldair  product  has  been  inspected, 
tested  and  is  guaranteed  subject  to  the 
following  for  a  period  to  one  year  from  the 
date 

of 

purchase 

against 

defects 

in 

workmanship  and  materials.  During  this 
period,  such  defects  will  be  rectified  by  repair 
or  replacement  of  the  product  purchased. 
Your  Warranty  becomes  invalid  if  in  our 
opinion  the  product  has  been  misused, 
incorrectly 

assembled, 

tampered 

with, 

connected  to  a  gas  supply  not  corresponding 
with  the  name  plate  specification,  or  not 
regularly maintained as per the 

“Maintenance” 

notes  at  the  end  of  this  user  manual.  The 
Warranty does not include any labour or other 
associated  expense  that  may  be  involved  in 
removal  or  installation  of  the  product.  Normal 
wear  &  tear  and  any  issues  involving 
spider/insect  web  build 

up’s  inside  gas  lines 

are expressly excluded.  
 
If  your  Goldair  product  fails  to  operate 
satisfactorily, please contact Goldair via phone 
in  the  first  instance.  To  obtain  a  repair  or 
replacement product under this Warranty, you 
will  need  to  produce  satisfactory  evidence  of 
date  of  purchase.  The  completed  Warranty 
and  purchase  receipt  must  be  presented  with 
the product. The Warranty should be filled out 
at the time of purchase. It is in your interest to 
make sure this is done.  
 
 
 

If  the  product  is  to  be  replaced  (cannot  be 
repaired)  then  that  replacement  will  be  of  the 
same  or  similar  product  or  accessory 
excluding  packaging,  instruction  card  etc. 
Where a replacement product is supplied, this 
shall  be  guaranteed  for  the  balance  of  the 
original Warranty period. 
 
Any  model  that  is  no  longer  available  will  be 
replaced by a model of a value and  with such 
features  as  we  consider  appropriate  in  the 
circumstances.  Goldair  Ltd  is  not  responsible 
for  freight  forwarding  charges,  losses  or 
damage in transit. 
 
If service is required after the Warranty period 
has  expired,  the  product  should  be  inspected 
by  a  qualified  gas  service  technician.  Service 
outside  of  the  Warranty  period  will  be  at  your 
cost. 
 
Consumers Guarantee Act (1993). 
In  accordance  with  the  above  act,  consumers 
are  advised  that:  The  manufacturer  does  not 
undertake  that  repair  facilities  and  parts  are 
necessarily available for this product. 
If  any  of  the  provisions  of  the  foregoing  are 
contrary  to  any  relevant  legislation,  then  that 
provision shall be deemed to be excluded from 
the Warranty and the rest of the provisions will 
continue to apply. 
 

Name ……………………………………………… 

Address …………………………………………… 

………………………………………………………. 

Suburb …………………………………………… 

Purchased from ………………………………… 

Date of purchase ………………………………… 

Name of product ………………………………… 

Model no ……………………………………………

 

  

IMPORTANT: Please retain this Warranty card 

One Year Warranty 

Summary of Contents for GPF42

Page 1: ...Operating Instructions 42L Chest Fridge Model GPF42 ...

Page 2: ... Fridge o It is vital for optimum use of the Chest Fridge that you Purge the gas line prior to attempting to ignite the Chest Fridge o Do not dispose of packaging until completely satisfied with assembly of your Chest Fridge Please refer to your user manual for operating instructions further information or trouble shooting before you call the Customer Service number listed within the user manual F...

Page 3: ...linder ON by rotating the knob to the open position Using a brush or spray bottle apply the soap solution to the gas line and each join in the gas line including The gas connection at the inlet of the Chest Fridge The gas hose The gas connection at the gas cylinder If bubbles appear there is a gas leak If the leak is at the connection re tighten and re seal If the leak is anywhere else or you cann...

Page 4: ...dial on the LPG Cylinder SLOWLY to the on position o Press the control knob in allowing gas to come up the line and bleed it pressing control knob in for not more than 1 2 minutes or until you smell gas o A five minute complete shut off period is necessary before lighting If a new tank has just been connected please allow at least one minute for the air in the gas pipeline to purge out at the High...

Page 5: ...pliance to the electricity or gas supply until all packing materials have been removed This appliance should not be used by children or infirm persons without supervision Never move the fridge by pulling on the power cord or gas connection Do not pull the cord to disconnect from an outlet Keep cord away from heated surfaces and inspect regularly for damage If the supply cord or gas connection is d...

Page 6: ...ructions could result in damage occurring to the appliance Goldair will not be held responsible if these instructions are disregarded The appliance must be protected from rain moisture and other atmospheric influences IMPORTANT This appliance is not designed for stacking with any other appliance DO NOT attempt to sit or stand on top of your appliance as it is not designed for such use You could in...

Page 7: ...d placing your Chest Fridge directly alongside any heat source or in direct sunlight as this will cause it to run for long periods If located next to a source of heat maintain the following minimum side clearances From cookers 100mm From radiators 300mm From freezers or other refrigerators 100mm Ensure that sufficient space is provided around the fridge to allow obstruction free air circulation Op...

Page 8: ...from the cigar lighter socket Operation with LPG gas bottle IMPORTANT Never use more than one energy source at a time Operation on gas is prohibited in closed areas in vehicles and on boats The appliance must be used in a well ventilated area when operating on gas This means that it can also be used under the canopy of a tent if sufficiently ventilated In all cases the location should be protected...

Page 9: ...nited 2 Hold the knob pressed in this position so that the flame remains burning It might be possible that this operation has to be repeated a couple of times especially if the appliance has not been used for a long time or if the gas cylinder has been changed 3 There can be air in the system which has to be forced out It is necessary to check that the pilot is lit by looking through the orifice a...

Page 10: ...ing abrasive products Never use a knife or other sharp tool to remove ice If the appliance is to remain unused for a longer period disconnect it clean it and leave the cover slightly open during storage to prevent unpleasant odours Put some talcum powder in the gasket of the lid If after such a period the fridge does not cool down switch it off again and leave it turned upside down for a few hours...

Page 11: ...If the battery is not charged disconnect fridge and re connect to a different battery Is the gas cylinder sufficiently filled If not fill the LPG cylinder Has the gas valve knob been pressed long enough when using the gas supply If not turn the fridge off leave for one minute and repeat the ignition procedure Has the thermostat knob been set to max position If not turn the fridge off leave for one...

Page 12: ...uld be filled out at the time of purchase It is in your interest to make sure this is done If the product is to be replaced cannot be repaired then that replacement will be of the same or similar product or accessory excluding packaging instruction card etc Where a replacement product is supplied this shall be guaranteed for the balance of the original Warranty period Any model that is no longer a...

Page 13: ...32 633 Website www goldair co nz TECHNICAL SPECIFICATION Model No GPF42 Battery 12 v 90W 7 5 A AC Supply 230 240V 50Hz 85 90W 0 38A DC Supply 12V 90W 7 5A Mains 240v 50Hz 90W 0 38 Amps Gas Type Butane and Propane Total Gas Consumption 15g h VOLUME NET 42L Refrigerant NH385g Class T Isolation Cyclopetane ...

Reviews: