background image

18

26

19

32

31

3

2

1

4

7

30

34

27

28

29

22

24

21

23

20

16

17

14

12

11

5

6

9

25

13

8

1

35

0

15

18

33

36

Squirt Assembly

Continued over page

Summary of Contents for Squirt

Page 1: ...Squirt Operator s Parts Manual GA8700276 REV 4 OCT 2020 ...

Page 2: ...this operating manual or by Goldacres its agents or employees The end user accepts all responsibility arising from that advice No part of this manual may be reproduced without written permission from Goldacres All photographs and technical information remain the property of Goldacres Introduction 3 Safety 4 Goldacres Warranty Statement 8 Terms Conditions 9 General Information Specifications 11 Dim...

Page 3: ...acres not only produce Australia s finest range of spraying equipment we also keenly value the unique relationship we enjoy with owners of our equipment We are pleased to welcome you as a Goldacres owner and look forward to making your spray applications as efficient as possible Please use this comprehensive resource to gain a full understanding of your equipment and don t hesitate to contact your...

Page 4: ...ier or lighter than water Example liquid urea has a density of 1 28 kg L and will therefore be significantly heavier than water if the tank is filled completely Regularly check the pump mounting bolts The pump will always vibrate to some degree when operating and this may work the bolts loose CAUTIONS A supply of fresh water should be with the equipment at all times Standard polyethylene tanks are...

Page 5: ...lose fitting clothing and safety equipment designed for the job Chemicals can be harmful to humans appropriate PPE should be used when handling chemicals Always refer to the chemical manufacturers label for guidelines on the appropriate PPE to use with the chemicals you are using Goldacres also suggest that you read and understand the following Australian standards Australian Standard for Chemical...

Page 6: ...nsibility of the owner operator to replace damaged and or missing safety decals Regularly review safety decals with operators It is very important to ensure that all new machine components and replacement parts include current hazard identification decals Replacement safety decals can be ordered from all Goldacres dealers Squirt Decal GA5064855 Safety Warnings GA5064860 ...

Page 7: ...motors and drivers Wheels tyres and rims Pins and bushes Pump housing Hydraulics Axle frame only Shockers and dampeners Wire cables Springs Drive chains Wheel bearings Failure caused by lack of lubrication not covered Warranty Exclusions Pump diaphragms Pump Seals Pump check valves Pump O rings Filters and filter screens Filter O rings Chemical Hoses Solenoid Diaphragms Hand Gun lance or wand seal...

Page 8: ...anship or materials used under normal use and service conditions The Warranty is not transferable The owner is responsible for the performance of regular maintenance and service as specified in the owner s operators manual applicable to the product Failure to follow regular maintenance as advised may invalidate the warranty The owner must provide the Goldacres Dealer with prompt written notice of ...

Page 9: ...rights under the provisions referred to in paragraphs a through to r of section 115 1 of the PPSA to the full extent permitted k to sign any documents or do any things which we may reasonably require to enable us to register a financing statement or financing change statement on the register as defined in the PPSA l to pay any costs we incur in registering and maintaining a financing statement inc...

Page 10: ...hat are not free of chemicals you must pay any costs incurred by us including the cost of our own staff in removing and disposing of the chemicals and cleaning the goods 22 If after 28 days of notifying you that your goods are ready for delivery we have received no communication from you we retain any rights under the Australian Consumer Law and Fair Trading Act 2012 Vic to sell the goods to recov...

Page 11: ...ill ensure the sprayer is able to perform to its capabilities Make sure the pump wires are connected up to the correct terminals red to positive black to negative if replacing battery Always flush pump with clean water after every use Prolonged chemical contact can severely damage valves diaphragms and seals Do not leave water in pump if sprayer is to be left in a cold environment The water may fr...

Page 12: ...12 Dimensions Squirt Model A B C Net Weight 30L 880 470 380 14 kg C B A NOTE Dimensions are in millimeters and are approximate only They may be subject to change without notice ...

Page 13: ...key to understand the LED light conditions on the charger 6 Once fully charged it is possible to confirm the battery condition by switching the power switch ON and OFF again and checking that the volt meter needle moves to the red or green zone Charge for longer if the meter stays in the yellow zone when doing this test 7 Make sure the power switch is set to OFF and disconnect the charger 8 Follow...

Page 14: ...iner 5 Follow the filling steps from previous section 6 Switch pump ON using On Off switch The pump will run until sufficient pressure is achieved and then the pump will stop 7 Use the lance by depressing the trigger The pump will then automatically maintain the correct pressure and flow depending on nozzle adjustment 8 Adjust the nozzle pattern as required by rotating the nozzle in the appropriat...

Page 15: ...rmed 1 Clean the sprayer thoroughly as described under flushing 2 Store the sprayer out of direct sunlight and where it will not be affected by frosts 3 Ensure that the main tank is empty 4 Protect hoses and electrical connections Pump Operation The 12 volt pumps are positive displacement diaphragm pumps which provide delivery upon demand They are self priming and are fitted with a pressure switch...

Page 16: ...ction in suction line Valves damaged Diaphragm damaged Pump sucking air Insufficient voltage Clean screen Check hoses fittings and tank outlet Check or replace valve kit Check or replace diaphragm Check suction line Check power supply Pump stopping and starting when not in use Valves damaged Insufficient voltage Damaged diaphragm Check valves Check power supply Check or replace diaphragm Maintenan...

Page 17: ... Switch diaphragm ruptured or pinched For punctured diaphragm if fluid is present at bottom drain holes Pump Will Not Shut Off Check Pressure switch equip Output line closed and no leaks For air trapped in outlet line or pump head For correct voltage to pump 10 Inlet Outlet valves for debris or swelling For loose drive assembly or pump head screws Pressure switch operation adjustment incorrect Ref...

Page 18: ...18 32 31 3 2 1 4 7 30 34 11 5 6 9 8 1 35 0 33 36 Squirt Assembly Continued over page ...

Page 19: ... Comes with lid GA5076885 above 4 GA5018521 Tank 30 Litre Squirt 1 5 Rotating shaft gasket 2 6 Wheel 2 7 Cover for wheel 2 8 GA5007132 Circlip Ext 15mm 2 9 Wheel axle 1 10 GA5008755 Filter screen in line 3 4 OD suit Pre 2012 1 GA5072550 Filter screen 40 Mesh Outlet fitting suit 2012 1 11 GA2000200 Hose Pressure 7mm Black 250psi 1 12 Fixed gasket 2 13 M5 screw 4 14 U type latch 2 15 Adjustable clam...

Page 20: ...el 1 28 Fixed buckle 1 29 See GA5025120 Volt Meter Supplied as part of GA5025120 1 30 GA5004493 Battery Rechargable Sealed lead acid 12V 7 2AH W 62 x H 95 x L 151mm Blade terminals 1 31 GA5004363 Plastic tube 4mm clear Cut to 280 mm 1 32 GA5045145 Elbow swivel push in 6mm Brass 1 8 BSPT 2 33 GA5023885 SK Replacement lance accessories 1 34 Drain Elbow 1 35 GA5053510 O ring 25 x 2 5 mm suit 2012 1 3...

Page 21: ...21 Notes ...

Page 22: ...22 Notes ...

Page 23: ...23 Notes ...

Page 24: ...24 www goldacres com au ...

Reviews: