TABLE SURFACE REPAIR: Our laminate surface is the most durable on the market, but it still may be
susceptible to damage over the air channels. A hard, sharp object (bottle, glass, mallet) smashed onto the surface
over the air channel may cause a dent. However, dents in the laminate surface are easily repaired. Use clear epoxy
to fill a dent in the surface. Allow the epoxy to set up slightly so it won’t run down into the air channel. If
necessary, use putty underneath to keep the epoxy from running down. Fill to the surface level and allow to
harden. Then use fine or extra-fine sandpaper to sand the patched area so it is level with the surrounding surface. If
you want, you can re-drill any air hole that had to be filled with epoxy.
For large dents or holes in the surface that go down into the air channel, insert a section of drinking straw into the
air channel to keep the epoxy from blocking the entire channel.
CLEARING MATERIAL FROM THE GOAL: If it becomes necessary to remove material that has been pushed
into the goal openings you can remove both the upper and lower puck housings or each one independently from
each other. See the below photos.
REPLACING BLOWER MOTOR FILTER: Once a year the blower motor filter should be replaced to help keep
clean air entering the blower and to also keep the original air flow for the playfield. To replace the filter open the
side access door and pull the dirty filter (located under the horizontal wall) toward you until it is clear from the
game. Replace this dirty filter with a 10"x 20"x 1" Furnace Air Filter which can be purchased at any hardware or
home improvement store. Note: Do not turn on the game with the blower motor filter removed. The blower motor