6
With 6 or 12 tubes, our Valve Output Stage is the best way to enhance your system for improved realism and musicality. Our
proprietary Totem-Pole Output Stage design, with six independent audio stages per tube, guarantees ultra-wide bandwidth
response and ultra-low distortion to deliver the purest audio signal ever.
Thanks to new audio inputs on the rear panel our valve output stages can be connected with up to two sources at the same
time using the TUBE INPUT for the Gold Note sources and the LINE INPUT for other manufacturers. The input can be easily
selected from the front panel for maximum convenience and ease of use.
USING TUBE-1012 AND TUBE-1006 WITH GOLD NOTE UNITS
1.
Connect the TUBE-1012/TUBE-1006 to the power outlet using the AC power cord included. The AC power socket is located
on the rear panel of the unit.
2.
Connect the TUBE-1012/TUBE-1006 to your Gold Note unit using the GN TUBE connection cable included. Please ensure to
use the TUBE INPUT connectors located on the rear panel.
3.
If you want the TUBE-1012/TUBE-1006 to automatically turn ON/OFF along your other Gold Note unit in master/slave mode,
connect your other Gold Note unit (master) to the TUBE-1012/TUBE-1006 (slave) through the GN LINK IN connector found on
the rear panel. If you want the TUBE-1012/TUBE-1006 to act as the master and control other Gold Note units, use the GN LINK
OUT connector instead.
4.
Turn to ON the MASTER SWITCH of the TUBE-1012/TUBE-1006.
5.
The TUBE-1012/TUBE-1006 will turn ON/OFF as it is now controlled by the other Gold Note unit. When ON, the Power Led is
blue as the TUBE INPUT is selected.
USING TUBE-1012 AND TUBE-1006 WITH OTHER UNITS
1.
Connect the TUBE-1012/TUBE-1006 to the power outlet using the AC power cord included. The AC power socket is located
on the rear panel of the unit.
2.
Connect the TUBE-1012/TUBE-1006 to your other units using the LINE INPUT connectors located on the rear panel.
3.
Turn to ON the MASTER SWITCH of the TUBE-1012/TUBE-1006.
4.
Press the Power On button and then press once the IN button located on the front panel to select the LINE INPUT as the
input - the Power Led will change from blue to green.
5.
Wait for approx. 30 seconds for the TUBE-1012/TUBE-1006 to reach the ideal operative temperature.
USING TUBE-1012 AND TUBE-1006
6