Mighty–Mite
A
LL
M
ODELS
#2035
1
This instruction booklet is very thorough and complete. Please take the time to read this entire
booklet before attemting to operate the appliance.
Your Mighty-Mite Commercial Popper is the finest 14 Oz. gas popper ever built. The special alloy
steel kettle is extra heavy to prevent burnouts or warping, and is made from excellent heat con-
ducting steel. Your Mighty-Mite has an extra heavy duty motor equipped with an extra fan and air
tunnel to direct cooling over the motor at all times allowing the motor to run cooler under heavier
popping conditions.
UNPACKING AND ASSEMBLY
After unpacking your Mighty-Mite, set it on a counter where you intend to use it and remove all
the tape. Make sure clearances around and overhead the appliance comply with the marking
on the data plate for the location you have selected. Attach the counterweight assembly as
per Drawing D-4957.
INSTALLATION
When installing your new Mighty-Mite Commercial Gas Popper, you must conform with local
codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1980.
When selecting a location for your new Mighty-Mite, pay close attention to the installation clear-
ances. The MINIMUM clearance for the sides is 6 inches; the MINIMUM top, back and frontal
clearance is 30 inches. This unit is certified for use on combustible surfaces.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
during pressure testing of that system at pressures greater than 0.5 psig (3.45 kPa).
During any pressure testing of the gas supply piping system at pressures equal to or less than 0.5
psig (3.45 kPa), the appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve.
This unit must be grounded in accordance with local codes; or, in the absence of local codes,
withthe National Electric Code - ANSI/NFPA No. 70-1981. Secure grounded wire to ground lug
provided inside the cabinet wiring junction box.
When wiring your new Mighty-Mite, refer to the wiring diagram located inside of the cabinet and in
this Instruction Manual (Drawing No. A-74500 for AC Model; Drawing No. A-74511 for DC Model).
Gas is safe when used properly, but can be very dangerous
when used improperly. We suggest that installation be carefully
made by only a qualified service person. Gas companies have
competent service people to provide safe installation.
a
Summary of Contents for Mighty-Mite 2035BG
Page 2: ...GAS SAFETY PRECAUTIONS ...
Page 8: ...Mighty Mite ALL MODELS 2035 6 BASO VALVE INFORMATION ...
Page 9: ...Mighty Mite ALL MODELS 2035 7 BASO VALVE INFORMATION continued ...
Page 10: ...Mighty Mite ALL MODELS 2035 8 KETTLE CROSS SECTION ASSEMBLY ...
Page 12: ...Mighty Mite ALL MODELS 2035 10 CABINET ASSEMBLY ...
Page 15: ...Mighty Mite ALL MODELS 2035 13 ELECTRICAL SCHEMATIC ...
Page 16: ...Mighty Mite ALL MODELS 2035 14 ELECTRICAL SCHEMATIC MODEL 2035DC ONLY ...