5.2

 

Installation 

Air source requirement 

  Standard air pressure: 0.63Mpa 

  Airflow > 300L/min 

 

Air hose: Exclusive air hose Φ10mm

 

Please ensure the input pressure and flow of the pneumatic motor (air 
motor consumption), otherwise the drive will not work properly. 

5.3

 

Attentions for air hose 

Please clean the tubing via compressed air before using. Make sure there 
is no dust or iron pin in the hose. 
 
It is not allowed to change the diameter of the air pipe, and the intake pipe 
must be larger than 3/8 inch or 10mm. Check whether there’s air leakage 
and  or loose connection with  the air hose and joint to prevent the 
compressed air leaking to the pneumatic tool. 
Fill lubricating oil: Remove the screw on the top of oil mist, fill the required 
lubricating oil and tighten the screw. 

Note

: The standard working pressure is 0.63Mpa, higher pressure may 

cause damage or accident to the gas motor. Lower pressure will not meet 
the designed requirements, and the will not be able to reach the maximum 
speed, the gas motor will not work normally. 
Be sure to fill lubricating oil before operating the peristaltic. 

5.4

 

Operation 

  Inserting the trachea into the drive to adjust the inlet of the filter 

component 

  The throttle valve of the panel is rotated clockwise to close. 

  Adjust the oil adjustment knob to zero 

  Install hose 

  Switch on the air source switch, adjust the drive pressure knob to 

make the pressure up to the specified value: 
0.4Mpa for YZ15/YZ25   
0.6Mpa for FG601S-Q with YZ35. 

Summary of Contents for FG600S

Page 1: ...GOLANDER PUMP FG600S 601S Q Pneumatic Motor Peristaltic Pump Operation Manual info golanderpump com http golanderpump com 1 678 587 8806...

Page 2: ...and Connectors 3 5 Operation Instructions 4 5 1 Before Operating 4 5 2 Installation 5 5 3 Attentions for air hose 5 5 4 Operation 5 6 Maintance and Service 6 6 1 Regular Maintenance 6 7 Dimensions mm...

Page 3: ...recommended in this manual Do not tear any labels off Please change the damaged label in time The drive is not insulated to prevent electric shock do not place it in a leakage electric field Warning T...

Page 4: ...3 Functions and Features Pneumatic motor for explosion protection environment Speed adjustable via pressure or throttle valve For workplace with explosion proof requirement or no power supply For abr...

Page 5: ...FG600S 601S Q Manual 3 4 Components and Connectors Pressure adjusting and filtering Pressure meter Throttle valve Pump head mounting plate Oil mist Pressure reducer Switch Air filter...

Page 6: ...nter clockwise to increase the speed Pressure adjusting and filtering To adjust pressure Show the current pressure and filter the air Oil mist Used for adding lubricating oil to the pneumatic motor 5...

Page 7: ...r leaking to the pneumatic tool Fill lubricating oil Remove the screw on the top of oil mist fill the required lubricating oil and tighten the screw Note The standard working pressure is 0 63Mpa highe...

Page 8: ...essure on the peristaltic pump is generally 0 5 06Mpa Higher or lower pressure will shorten the lifetime of the product The working pressure should be around 0 6Mpa The input air must contain enough l...

Page 9: ...the hose position in the pump head often helps prolong the service life of the tubing 7 Dimensions mm Figure 2 Components and connectors 8 Specifications FG600S 601S Q Flow Range YZ15 9 2300 ml min Y...

Page 10: ...9 Suitable Pump Heads and Tubing Liquid water Condition Standard atmosphere temperature and pressure length of input or output is 1 meter Pump and liquid on the same level Data is only for reference...

Page 11: ...rpm Tubing 15 24 35 36 150 250 425 575 725 350 583 992 1342 1692 600 1000 1700 2300 2900 9 2 FG601S Q KZ25 KZ25 L 3 rollers ml min Speed rpm Tubing 15 24 35 36 150 370 650 1225 1500 350 863 1517 2858...