ON – activates system and drops masks if automatic function fails.
3
Passenger Oxygen On Light
Illuminated (amber) – passenger oxygen system is operating and masks have
dropped.
Oxygen Mask Panel
1
Oxygen Flow Indicator
Indicates a colored cross when oxygen is flowing.
2
TEST/RESET Switch
1B401, 1B402, 1B801 - 1J594
Push –
• with the left oxygen mask panel door closed and the OXY ON flag not
displayed, turns oxygen on momentarily to test the regulator
• with the left oxygen mask panel door closed and the OXY ON flag
displayed will turn oxygen off and disable the mask microphone and
enable the boom microphone.