Caramatic SwitchTwo
22
part no. 02 489 89
The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
The LPG cylinder(s) must be upright when gas is being withdrawn.
Gas is withdrawn only from the gaseous phase.
The gas cylinder(s) must be secured so that it cannot topple over.
Protect gas cylinder(s) against radiant heat or heat from heating appliances.
Observe the installation regulations in the respective countries.
TROUBLESHOOTING
Fault cause
Action
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the building.
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
No gas flow.
Gas feed is closed.
Open the gas cylinder valve, shut-off fittings or excess
flow device.
MAINTENANCE
Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.
REPLACEMENT
If there is any sign of wear or if the product or parts thereof are damaged, it must be
replaced. When the product has been replaced, observe the steps ASSEMBLY, LEAK
TESTING, and START-UP. To ensure that the installation works faultlessly under normal
operating conditions, it is recommended to replace system parts subject to wear or ageing,
e.g. pressure regulators, hose assemblies, shut-off devices, as required:
•
Recommendation: replacement times 5 years.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.