22 / 84
Artikel-Nr. 02 491 50 e
Always turn the changeover device as far as it will go to the operating or reserve side!
No intermediate position!
Type of withdrawal
Reserve
Automatic changeover valve
Operation
Operation
GREEN
on the
changeover device points
to the cylinder(s) on the
operating side.
The visual indicator is at
GREEN "operation"
.
Reserve - operating side
is empty
GREEN
on the
changeover device points
to the cylinder(s) on the
empty operating side. The
visual indicator is at
RED
"reserve"
.
Type of withdrawal
Operation
Reserve
Cylinder replacement
during operation
Set the changeover device
so that
GREEN
is pointing
to the cylinder(s) on the
reserve side. The visual
indicator changes from
RED "reserve"
to
GREEN
"operation"
.
Perform LEAK TESTING.
Close the gas cylinder valve(s) for storage and transport.
The protective cap serves as additional protection against the escape of gas in the event of
leaks.
Mount the protective cap to secure the gas cylinder valve(s) during transport.
180°