background image

NEW Advanced Nozzles

 

Nozzle Protector to avoid BLOCKAGES 

 

Reducing  Operators  Contamination  Risk

 

NEW TOOLS TO IMPROVE IRS 

APPLICATIONS 

Low Pressure Control Flow Valve (CFV): 

Uniform Insecticide Dosage 

Considerable  variation  in 
the DOSAGE of insecticide 
(aprox.  ±25%)  measured 
on wall surfaces. 

Conclusions: 

1.BETTER 

EFFICIENCY: 

uniform 

dosage 

of 

insecticide 

is 

sprayed 

during all the operation. 
 

2.SAVING  WATER: 

25  % 

less  water  is  used  (7,5  ltr 
instead of 10 ltr.) 

 

Conclusions: 

7,5 

Pressure gauge. 
Tank  pressure  and  nozzle 
flow varies condierably 
Operator  has  to  decide 
when to STOP 

Nozzle flow rate constant 

 

Automatic STOP 

. . 

Summary of Contents for iK VECTOR CONTROL

Page 1: ...SPRAY OPERATOR S MANUAL to ensure the correct usage of the IK Vector Control sprayer VECTOR CONTROL BY EXPERTS FOR EXPERTS...

Page 2: ...with Control Flow Valve Double filtering system Nozzle protector to avoid nozzle blockages Equipped with long life nozzles with excellent erosion resistance properties 3 even fan nozzles for IRS and 1...

Page 3: ...re than 50 years Goizper has developd an extensive network of distributors backed up by its own 10 delegations 4 in Europe 1 in South East Asia 1 Middle East 2 in Africa 2 in America Goizper develops...

Page 4: ...NEW ADVANCED MATERIALS and New MANUFACTURING PROCESS...

Page 5: ...iderable variation in the DOSAGE of insecticide aprox 25 measured on wall surfaces Conclusions 1 BETTER EFFICIENCY uniform dosage of insecticide is sprayed during all the operation 2 SAVING WATER 25 l...

Page 6: ...A B B 1 ASSEMBLY...

Page 7: ...1 ASSEMBLY 1 1 Straps 1 2 Hose...

Page 8: ...1 ASSEMBLY 1 3 Tie all nuts tightly 1 4 Nozzle Orientation...

Page 9: ...1 ASSEMBLY 1 5 Nozzle Protector 1 6 Parking Lance OPEN CLOSE...

Page 10: ...1 ASSEMBLY 1 7 Hose Parking 1 8 Nozzle storage box...

Page 11: ...2 CARRYING 2 1 BACK or ONE Shoulder 2 2 Strap length rregulation In the BACK One Shoulder...

Page 12: ...3 FILLING AND PRESSURIZING 3 1 Release pressure before opening the tank 3 2 Pump parking...

Page 13: ...3 FILLING AND PRESSURIZING 3 3 Correct insecticide mixing 3 4 Pressurizing 7 5 ltr 4 ltr MAX 3 4 ltr 50...

Page 14: ...4 CALIBRATION AND SPRAYING 4 1 Nozzle Protector 4 2 Calibration...

Page 15: ...BRATION AND SPRAYING 4 4 Control Flow Valve CFV 7 5 AUTOMATIC FLOW RATE REGULATION Sprayable wall surface area 250 m2 AUTOMATIC SPRAYING CUT OFF when the minimum recommended pressure has reached in th...

Page 16: ...5 SPRAYING TECHNIQUE...

Page 17: ...6 CLEANING AND MAINTENANCE 9 Open the lid of the Control Flow Valve and clean it thoroughly with water...

Page 18: ...6 CLEANING AND MAINTENANCE Nozzle cleaning MAINTENANCE OIL or GREASE...

Page 19: ...G AND MAINTENANCE Spare parts and service kit Handle filter w joints Elbow with nozzle Viton Collar seal Viton Closing valve Safety valve Viton Round gaskets Available with the most frequently request...

Page 20: ......

Reviews: