Chapter VIII. Specifications

 

Capacity 

500VA 

1KVA 

2KVA 

3KVA 

5KVA 

10KVA  15KVA  20KVA  30KVA  50KVA 

Input

 

Phase 

Single Phase 

Three Phase 

Voltage 

220V±10% 

380V±10% 

Frequency 

50Hz, 60Hz 

O

ut

put

 

Phase 

1Φ2W 

Voltage 

Low grade 0-150V AC / High grade 0-300V AC 

Frequency 

40Hz-120Hz (120Hz-499.9Hz Specified) 

C

u

rre

n

L=110V 

4.2A 

8.4A 

16.8A 

25A 

84A 

84A 

125A 

168A 

250A 

420A 

H=220V 

2.1A 

4.2A 

8.4A 

12.5A 

21A 

42A 

62.5A 

84A 

125A 

210A 

Display 

Voltage, Current, Frequency, Power, Power Factor. 

Voltage Regulation 

0.10% 

Load Regulation 

0.50% 

Total Harmonic 

Distortion (THD) 

1% (Pure resistive loads) 

Frequency Stability 

0.01% 

Voltage Resolution 

0.1V 

Frequency Resolution 

0.1 Hz 

Current Resolution 

0.01A 

1A 

Measurement 

Accuracy 

Voltage 

0.5%FS+5dgt 

Current 

0.5%FS+5dgt 

Power 

0.5%FS+5dgt 

Frequency  0.01%FS+5dgt 

Setting 

Accuracy 

Voltage 

1%FS 

Frequency  0.1%FS 

Parameter Sets 

10 sets (M0 - M9), record voltage, frequency and running time 

Communication 

Interface 

RS232C (Optional) 

Protection 

Overcurrent, over temperature, overload, short circuit etc. 

Operating Environment  0-40

, 20-80%RH 

 

 

 

 

Summary of Contents for HZ-60-1101

Page 1: ...Frequency Converter Programmable 50Hz 60Hz 400Hz Frequency Converter Solutions for Converting 110V 60Hz to 220V 50Hz 120V 60Hz to 240V 50Hz 230V 50Hz to 110V 60Hz etc Power Capacity from 500 VA to 50...

Page 2: ...Operation Panel and Functions 6 V Operating Guide 7 Menu Selection Parameter Setting Procedure Specific Operation Settings VI Placement 8 VII Installation 9 12 Wiring Precautions Wiring Diagram Wire D...

Page 3: ...stallations according to different capacities and voltage levels choose an appropriate configuration and wire diameter Do not overload the frequency converter and wire to prevent the electric shock or...

Page 4: ...dule design to reduce circuit complexity enhance frequency converter stability and reduce power consumption And the isolation transformers completely isolate the mains and the loads in order to improv...

Page 5: ...rt circuit current limitation High accuracy digital key input voltage frequency Fault code records easy for troubleshooting Applications Laboratory standard power supply Air compressor testing Monitor...

Page 6: ...panel Input Switch SET set voltage and frequency values in standby mode OK button to confirm W PF power and power factor switch Up Down adjust voltage Left Right adjust frequency M1 M4 shortcut of pa...

Page 7: ...normality 5 Program Settings press up down buttons to switch terminate parameter sets elect parameter sets and running mode press left right buttons to change the sub options of terminate parameter se...

Page 8: ...y converter with care in moving to avoid collision Placement Do not put the frequency converter on uneven or inclined place Avoid direct sunlight rain or humid place Keep it away from fire and high te...

Page 9: ...er to electrician wiring regulations or following the wire diameter reference table Avoid the switch of the frequency converter share with other appliances Use O type wiring terminals make sure it s w...

Page 10: ...0V 136 4A 125 0mm2 3 4W 220V 380V 3 3W 380V 3 Model Input Output GoHz Max I P Current Protection Breaker Power Wire Max O P Current Power Wire 3306 6KVA 12 6A 30 0A 2 0mm2 110V 18 2A 220V 9 1A 3 5mm2...

Page 11: ...wire systems are 100V 110V 115V 120V 127V 132V 139V 220V 230V 240V 254V 277V If the voltage between Ground Wire and Neutral Wire is higher than 5V or the equipment has specific requirement please find...

Page 12: ...unding for the best 6 Ground Types Item Applications Resistance values 1 Low voltage power supply system or high voltage electrical equipment of three phase four wire multi grounded systems grounding...

Page 13: ...Display Voltage Current Frequency Power Power Factor Voltage Regulation 0 10 Load Regulation 0 50 Total Harmonic Distortion THD 1 Pure resistive loads Frequency Stability 0 01 Voltage Resolution 0 1V...

Page 14: ...N to reboot 2 Make sure the loads are within the frequency converter s capacity No output voltage 1 Is the fuse burn down or not 2 Is it overloaded 1 Check the fuse and replace the fuse with same spec...

Page 15: ...s windy and dusty pay more attention to make the frequency converter clean or do more frequent maintenances Maintenances Turn off the power switch Clean inner dusts Wipe the cabinet cover and venting...

Reviews: