Goddess RDB0116GW7 User Manual Download Page 12

Note:

During the period of high relative humidity , moisture may form on the surface of the refrigerator. 

It is not malfunction. You may just wipe it up yourself. If your refrigerator is still not functioning 

properly after making the above checks ,please contact with the maintenance service department 

without any delay .

INFORMATION LETTER :

Brand

GODDESS

Model

RDB0116GW7

Type of appliance 

3)

7

Energy class       

(A - low consumption,      

G - high consumption)

A

Consumption for 365 days 

1)

9

Net capacity total(I)

118

thereof : fridge compartment (I)

89

thereof : freezer compartment(I)

9

Designation of freezer compartment

*(***)

Time of storage in case of the power 

interruption (hrs)

10

Freezing capacity (kg/24 hrs)

2.0

Climatic class 

2)

N

Noise level (dB(A))

9

1)

 Consumption of energy in kWh/year, based on the results of the 24hrs-standard test.

  Real consumption depends on the way of use and on the allocation of the appliance.

2)

 SN : surrounding temperature from + 10°C do + 32°C  

  N   : surrounding temperature from + 16°C do + 32°C        

  ST : surrounding temperature from + 18°C do + 38°C        

  T   : surrounding temperature from + 18°C do + 43°C   

3) 

3 = fridge with low-temperature compartments

  4 = fridge with low-temperature compartments (*)

  5 = fridge with low-temperature compartments (**)

  7 = fridge with low-temperature compartments *(***)

  8 = freezer 

 

     

NOTES:

We reserve the right to make technical changes without notice in the interest of improvement.

EN - 12

Summary of Contents for RDB0116GW7

Page 1: ...RDB0116GW7 N VOD K POU IT USER MANUAL Chladni ka Refrigerator...

Page 2: ...isem v tomto n vodu k pou it Obecn Tento typ chladni ky vyu v vysoce inn kompresor a klasick uspo d n Poskytuje v hody n zk spot eby elekt iny dynamick mraz c kapacity a snadnosti pou it Ilustrace usp...

Page 3: ...pou it m chladni ky je t eba zkontrolovat zda je p ipojovan nap t stejn jako p ede psan nap t 2 S ov z str ka by m la b t zapojena do samostatn z suvky aby nedoch zelo k p eh v n elektrick ho kabelu v...

Page 4: ...fl ku termostatu Pro b n provoz je nejvhodn j nastaven termostatu na hodnoty 3 4 m je hodnota termostatu vy t m je v t chlad c kapacita 3 Ned vejte do chladni ky p li velk mno stv potravin Neotv rejte...

Page 5: ...te se zda Je spr vn nastavena teplota Kolem chladni ky je dostate n prostor Dve e nejsou otv r ny p li asto a p li dlouho Chladni ka nen pod p m m slune n m sv tlem ani bl zko tepeln ho zdroje V chla...

Page 6: ...n b h teploty 10 Mraz c v konnost kg 24hod 2 0 T da klimatu 2 N Hlu nost 39 1 Spot eba energie v kWh rok zalo en na v sledc ch normalizovan zkou ky po dobu 24 hod Skute n spot eba energie z vis na zp...

Page 7: ...yklace takov ho elektrick ho a elektronick ho za zen V Evropsk unii a v ostatn ch evropsk ch zem ch existuj sb rn m sta pro pou it elektrick a elektronick za zen T m e zajist te spr vnou likvidaci v r...

Page 8: ...ype of refrigerator is widely used in places such as hotels offices students dormitories and houses It adopt high efficiency compressor and classic structure distribution It enjoys the advantages of l...

Page 9: ...d that the voltage used should be the same as the rated voltage before the refrigerator is used 2 The power plug should have its own separated socket in order to prevent the electric wire from being o...

Page 10: ...by turning the thermostatic dial setting of the thermostatic dial at 3 4 is the most suitable for general operation The thermostatic dial number higher the refrigeration capability stronger 3 Don t pu...

Page 11: ...e thermostat is at the correct setting There are enough space around the refrigerator The doors are not opened too frequently and for too long The refrigerator is not under direct sunlight or placed n...

Page 12: ...zer compartment Time of storage in case of the power interruption hrs 10 Freezing capacity kg 24 hrs 2 0 Climatic class 2 N Noise level dB A 39 1 Consumption of energy in kWh year based on the results...

Page 13: ...trical electronic equip ments waste In the European Union and Other European countries which there are separate collection systems for used electrical and electronic product By ensuring the correct di...

Page 14: ......

Reviews: