All On/All Off

The PD300EMZ5-1 supports the ALL ON / ALL OFF commands. The PD300EMZ5-1 can be set 
to respond to ALL ON and ALL OFF commands four different ways.

Refer to your Controller for information on how to set the PD300EMZ5-1 to operate in the 
manner you desire. Some Controllers may be only able to set certain settings of ALL ON/ALL 
OFF response.

The four different ways the PD300EMZ5-1 can be setup to respond to ALL ON and ALL OFF 
commands are:

1. 

Responds to ALL ON or the ALL OFF command.

2. 

Responds to ALL OFF command but will not respond to ALL ON command.

3. 

Responds to ALL ON command but will not respond to ALL OFF command.

4. 

Responds to ALL ON and the ALL OFF command.

CONFIGURATION

Adjusting Dim Rate

Dim Level

The brightness setting of the Dimmer is called the Dim Level. When the Dim Level is adjusted, 
the rate that Dim Level changes depends on the Dim Step (Parameter 7) and Dim Timer 
(Parameter 8) values. These values can be changed instantly to allow various scenes and 
effects.  These values can also vary between local control, remote commands from the hub or 
associated device and ALL ON / OFF commands.

Dim Step (remote and local)

Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer 
will change each time the Dim Timer expires.

Dim Timer (remote and local)

The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value 
indicates in 10 millisecond resolution, how often the dim level will change.

Examples:

• If the Dim Timer parameter value is set to 1, every 10mS the Dim Level will change by the 
Dim Step value.

• If the Dim Timer parameter value is set to 255, every 2.55 seconds the Dim Level will change 
by the Dim Step value.

With the combination of the two parameter values that control the dim rate, the dimmer can 
be adjusted to dim from maximum to minimum or minimum to maximum at various speeds 
between 10 millisecond and 252.45 seconds (over 4.25 minutes).

Parameter

Length

Valid

Values

Confi guration Option

7

1 byte decimal

1 – 99

Remote Dim Step (default = 1, 1 step)

8

2 byte decimal

1 – 255

Remote Dim Time (default = 3, 30 mS)

9

1 byte decimal

1 – 99

Local Dim Step (default = 1, 1 step)

16

2 byte decimal

1 - 255

Local Dim Time (default = 3, 30 mS)

17

1 byte decimal

1 - 99

AllSwitch Dim Step (default = 1, 1 step)

18

2 byte decimal

1 - 255

AllSwitch Dim Time (default = 3, 30 mS)

LED Intensity

You can set the intensity of the LED to fi t the environment the PD300EMZ5-1 is being used in 
from off to full brightness. This is done by changing Parameter 2. 

Parameter

Length

Valid Values

Confi guration Option

2

1 byte

Decimal

0 - 100

0 = OFF

1 = Very Dim

100 = Full Brightness (default)

Power Monitoring

The PD300EMZ5-1 provides a visual display of the amount of energy being 
consumed when the switch is turned on by illuminating the LEDs in one of 5 
different colors.

Energy

0 to 2 Watts

White

3 to 60 Watts

Green

60 to 100 Watts

Blue

101 to 200 Watts

Yellow

201 to 300 Watts

Red

The Power Monitoring can be turned off utilizing Parameter 11. When turned off, the 
PD300EMZ5-1 will no longer illuminate the LED to indicate any energy use and periodic 
reports to the hub on energy use will also be turned off.

Parameter

Length

Valid Values

Confi guration Option

11

1 Byte

Decimal

0

Power Monitoring OFF

1

Power Monitoring ON 

(Default)

The duration the LED will change color to indicate the amount of energy being 
used can be set using Parameter 12. After displaying the “energy used” color, the 
LED will revert to OFF or ON (white) as determined by confi guration parameter #3.

Parameter

Length

Valid Values

Confi guration Option

12

2 Byte

Decimal

1 - 254

Number of seconds LED 

displays power level usage.

Default = 60

255

Power Level usage 

continuous ON

The PD300EMZ5-1 supports the Confi guration command.

 Each unit can be confi gured to 

operate slightly differently than how it works when you fi rst install it. 

Using the Confi guration command you can confi gure the following:

Night Light

By default, the LED on the PD300EMZ5-1 will turn OFF when the load attached is turned ON. 
To make the LED turn ON when the load attached is turned ON, set Parameter 3 to a value of 1.

Parameter

Length

Valid Values

Confi guration Option

3

1 Byte

Decimal

0

LED ON when the load is on, and OFF when 
the load is off

1

LED OFF when the load is on, and ON when 
the load is off 

(default mode)

2

LED is always on

3

LED is always off

Over-The-Air (OTA) Update

A Quadruple tap of the switch enables the fi rmware update mode. Firmware update mode 
must be entered before the system Controller sends the fi rmware update command to begin 
downloading new fi rmware. Firmware update mode is enabled for 60 seconds after the 
quadruple tap. If the Firmware update does not begin before the end of the 60 seconds then 
fi rmware update mode is exited returns to normal operation. The LED “winks” twice per second 
indicating it is in fi rmware update mode.

Resetting to Defaults

Each confi guration Parameter can be set back to its default setting by setting the default bit 
in the Confi guration Set command. See your Controller’s instructions on how to do this 
(and if it supports it). All confi guration commands will be reset to their default state when the 
PD300EMZ5-1 is excluded from the Z-Wave network by using the Controller to reset the node.

SPECIFICATIONS

Power:

 

120 VAC, 60 Hz

Signal (Frequency):

 

908.42 MHz / 916 MHz

Maximum Load: 

 

300 W for lamps only 120 VAC

 

Range:  Up to 130 feet line of sight

NOTICES

Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs and its subsidiaries in the United 
States and other countries.
Covered by one or more claims of patents: http://sipcollc.com/patent-list/ and http://intusiq.com/patent-list/
Terms and Conditions pertaining to the sale of this Nortek Security & Control wireless mesh network product 
are available at http://nortekcontrol.com/terms_conditions.php

CAUTION: 

Do not connect grounding type plugs (3) three prongs, to a non-grounding 

receptacle (2) two prongs.

REGULATORY INFORMATION

We, Nortek Security & Control, LLC, of 1950 Camino Vida Roble STE 150, Carlsbad, CA 92008, declare 
under our sole responsibility that the device PD300EMZ5-1 complies with Part 15 of the FCC rules.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) This device must accept any interference received, 
including interference that may cause undesired operation.

FCC Notice

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
•  Consult the dealer or an experienced radio/TV technician to help.

Changes or modifi cations not expressly approved by the party responsible for compliance could void 
the user’s authority to operate the equipment

IC Notice

This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil 
est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation 
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur 
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 
compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to 
the following two conditions: (1) this device may not cause interference, and (2) this device must accept any 
interference, including interference that may cause undesired operation of the device.

WARRANTY

What is Covered?

Nortek Security & Control (“NS&C”) warrants to consumers who purchase this product for personal, 
family or household purposes new from NS&C directly or from an authorized NS&C dealer, that the 
product will be free from defects in materials and workmanship for a period of (1) year from the date 
of purchase. This warranty only applies if the product is installed at a residence in the 50 United 
States or District of Columbia, and only at the site of the original installation. It is not transferable. This 
warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product to us and we will, at our option, either 
repair or replace it. This warranty does 

not

 cover the cost of labor to remove a defective part or product or to 

reinstall any repaired or replacement part or product
This warranty does 

not

 cover defects or damages caused by improper handling, maintenance, storage, 

installation, removal or re-installation, misuse, non-factory authorized modifi cation or alteration, use of 
incompatible accessories, electrical power problems or surges, impact by foreign objects, accident, fi re, acts 
of God, normal wear and tear or shipping damage other than a shipment from NS&C. Note that all NS&C 
products are designed to be installed, removed and serviced by trained individuals or professionals.
Keep your original sales receipt as it will be required to obtain warranty service.
This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product 
under this warranty. No person is authorized to extend or otherwise modify this warranty.

How do I Obtain Warranty Service?

To obtain warranty service, email our Returns Department at [email protected]. Include your name, 
address, telephone number, the model number of your product, a copy of your original sales receipt, and 
a description of the problem. Unless we need to discuss the situation further with you, you will be emailed a 
Return Authorization Number and shipping instructions. If we need to discuss the situation further with you, 
we will call or email you. NS&C may require troubleshooting on installed product before a Return Authorization 
Number is issued. Anything shipped to us without a Return Authorization Number will be automatically returned 
unopened. You are responsible for the charges for shipment to us, unless you are a California resident.

Limitations

THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply 
to you.

NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE 
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation 
or exclusion may not apply to you.

This warranty gives you specifi c legal rights, and you may also have other legal rights which vary from State 
to State.

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,PD300EMZ5-1,GO CONTROL; P/N 10008250 B: INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 14.000”; TOLERANCE ± .125”; SCALE: 1-1 FOLDING: FOLD PAGE 4 X FINISH WITH  LOGO SHOWING; 

PAGE 2 OF 2

Copyright © 2017 Nortek Security & Control LLC 

10008250 B

Reviews: