background image

 

Go Power! SW150, SW300 Inverter 

Owner’s Manual

 

 

5

 

3.2  Front view GP-SW300: 

 

 

 

 

 

 

 

 

 

 
 
 

a)  ON / OFF switch: 

Power ON/OFF switch, leave in the OFF position during installation.  

 
b) AC 

outlet: 

Outlet sockets available: 

North America 

 
c) Remote 

port. 

 
d) Power 

status 

LED. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

a. ON /OFF switch

c. AC outlet

d. Power status LED 

 

c. Remote port

Summary of Contents for GPSW-150

Page 1: ...Go Power Manual GP SW150 Inverter GP SW300 Inverter Go Power Electric Inc PO Box 6033 Victoria BC V8P 5L4 Tel 866 247 6527 Fax 866 607 6527 Email info gpelectric com...

Page 2: ...MAIN FUNCTION 4 4 INSTALLATION 7 5 OPERATION 9 6 OPERATING LIMITS 10 7 TROUBLESHOOTING 10 8 MAINTENANCE 11 9 WARRANTY 11 Go Power Electric Inc PO Box 6033 Victoria BC V8P 5L4 Toll Free Tel 866 247 65...

Page 3: ...arity Fuse Over Under Voltage Over Temperature Low Battery Alarm 2 10 5 V 21 0 V Low Battery Shut Down 2 10 0 V 20 0 V Operating Temperature Range 0 40 C 32 F 104 F Storage Temperature Range 30 C 70 C...

Page 4: ...ain function 3 1 Front view GP SW150 a AC outlet Outlet sockets available North America b ON OFF switch Power ON OFF switch leave in the OFF position during installation c Remote port d Power status b...

Page 5: ...2 Front view GP SW300 a ON OFF switch Power ON OFF switch leave in the OFF position during installation b AC outlet Outlet sockets available North America c Remote port d Power status LED a ON OFF swi...

Page 6: ...y or other power source black is negative red is positive A reverse polarity connection will blow the internal fuse and may damage inverter permanently c Chassis ground or to vehicle chassis using 8 A...

Page 7: ...hether the inverter is switched on or off If you are using more than one AC source for the AC wiring or AC loads it is highly recommended that you install an automatic transfer switch GP TS available...

Page 8: ...se into the positive lead Fuse should be located within 12 of battery Ensure all connections are tight and secure 4 4 Grounding The power inverter has a lug on the rear panel Chassis Ground This is to...

Page 9: ...ode and there is no AC output Some common faults include 5 2 1 Over voltage indicator Red LED Blinking Fast The over voltage indicator indicates that the power inverter has shut itself down because it...

Page 10: ...4 V The power inverter will shut down if the input voltage drops below 10 20 V This protects your battery from being over discharged The power inverter will also shut down if the input voltage exceeds...

Page 11: ...k and replace fuse OBSERVE CORRECT POLARITY No output voltage Over Load indicator ON Short circuit or wiring error Check AC wiring for short circuit or improper polarity hot and neutral reversed 8 Mai...

Reviews: