If PV power is insufficient or too many loads are drawing
power from the battery, the controller will not be able to
charge the battery to the target charging voltage.
Auto Equalize:
The GP-PWM-30-SB has an automatic equalize feature
that will charge and recondition your batteries at least once a month at a
higher voltage to ensure that any excess sulfation is removed.
This mode will not be entered unless you are using a
flooded battery.
7.4
Viewing the Controller Display Information
To toggle between Battery Voltage, PV Charging Current, Battery State
of Charge (SOC), and ampere hours charged since last reset, press the
B Button
.
Equalization Charge
@
25°C
:
Applied for 2 hours every 28
days and if the battery voltage
drops below 12.1 volts.
N/A
N/A
14.9 VDC
(+/-0.1V)
N/A
Absorption Charge voltage
for LiFePO
4
:
Set to 30 minutes every
morning.
N/A
14.4 VDC
Float Charge voltage for
LiFePO
4
:
N/A
14.0 VDC
Temperature Compensation:
-24mV/K
None
If a charging cycle is unable to complete in a single day, it will continue the
following day.
The terms SEALED/GEL, AGM, LFP (Lithium) and FLOODED are generic
battery designations. Choose the charging profile that works best with your