Go Power GP-LiFePO4-100 Quick Start Manual Download Page 2

Wiring Guide

The illustrations below show how to properly wire lithium batteries.

Minimum 1in gap inbetween batteries and

between batteries and battery enclosure walls

All battery interconnects to 

be equal length and gauge

100Ah Lithium Battery Bank Parallel Connection

Note: Up to a maximum 4x 100Ah lithium batteries may be connected in parallel. Lithium batteries may not 

be connected in series. New batteries should never be connected to old batteries. All batteries should be charged to 

a minimum of 13V before connecting them together.  

Connect negative terminals together

Connect positive terminals together

All battery to busbar 

connections to be equal 

length and gauge

Ex) Inverter

Ex) Converter

Ex) Solar Controller

All busbar connections to external devices (inverter, converter, solar controller, etc.) to be 

equal length and gauge, sized appropriately for each device with suitable positive circuit protection 

(fusing or breakers).   

Positive busbar

Negative busbar

All battery interconnects, busbar and device connections to resist vibration by using nylon

insert lock nuts, thread locking fluid, or lock washers (split lock or external tooth).   

Split lock washer

External tooth 

lock washer

Do NOT stack smaller 

terminals under large ones

Battery Bank Terminal Connections

Ensure correct strip length and that 

stripped wires are completely inserted 

into terminal before crimping

 Minimum 1in gap inbetween batteries 

Torque battery terminals to

11-14.7 N*m ( 97.3-130 in*lbs)

Terminals with open-end crimp 

barrels may be used to verify wires 

are fully inserted before crimping