TECHNICAL DATA
INSTALLATION
Model
FT-30EII
Main Supply
220-240 V~
Frequency
50 Hz
Output
40W
Protection Class
II
Speed
3
Timer
No
Maximum air flow (F)
26,55 m
3
/min
Power consumption (P)
34,03 W
Service value (SV)
0,78 (m
3
/min)/W
Fan sound power level(LWA)
50,735 dB(A)
Maximum air velocity (c)
2,42 m/s
Measuring standard of
service value
EN 50564:2011
IEC 60879 :1986 + cor1:1992
EN 60704-2-7:1998
Contact details for obtaining
more information
Jumbo-Markt AG
Industriestrasse 34, 8305 Dietlikon
Tel. +41 848 11 33 11
2