EN

2 - SAFETY

2.1 - Safety Measures

1 - GENERAL WARNINGS

 IMPORTANT: It is essential to have understood the entire instruction manual before 

performing any operation so as to safeguard the operator and to avoid potential product damage.

Storing the manual: 

This manual must be kept intact and fully legible. The end user and the skilled 

technicians authorised with installation and maintenance of the product in question must be able to consult it at all 

times.

Reproduction rights:

 This manual is the property of ADAM PUMPS S.p.a. Soc. con Socio Unico , which is 

the sole owner of all rights provided for by applicable law, including without limitation copyright rules. All rights 

under these rules belong to ADAM PUMPS S.p.a. Soc. con Socio Unico : reproduction, even partial, of this 

manual, its publication, modification, transcription, public disclosure, distribution, marketing in any form, translation 

and/or development, loan, or any other activity reserved by law to ADAM PUMPS S.p.a. Soc. con Socio Unico 

 CAUTION: Live equipment.

 Contact between the power supply and the liquid to be pumped must 

be prevented at all costs. Connect all equipment in the work area to the earthing system. 

Immediately stop operation in the event of electrostatic discharges or if you feel a shock. Do not use 

this device until the problem has been identified and duly solved.

IMPROPER USE OF THE PRODUCT

Improper use can result in serious injury or death. Do not operate the unit when fatigued or under the influence of 

alcohol or drugs. Do not leave the work area while the product is powered or under pressure.

Turn all equipment off when not in use. Do not blow compressed air through the meter. Prevent liquids from drying 

inside the meter.Do not alter or modify the product. Alterations or modifications to the product may invalidate the 

approvals and cause safety hazards. Place the pipes and cables away from traffic, sharp edges, moving parts, and 

hot surfaces. Do not twist or bend the hoses too much, do not move the product by the hoses. Keep children and 

animals away from the work area. Observe all of the safety regulations in force.

ALWAYS KEEP A WORKING FIRE EXTINGUISHER IN THE WORK AREA.

 

CAUTION: Flammable liquids. Observe the precautions against the risk of fire or explosion. 

Read the safety data sheets to know the specific hazards of the fluids used. If there are flammable 

liquids in the work area (petrol, glass cleaning liquids, etc.), you must be aware that the vapours 

produced can ignite and explode. Only use the product in well-ventilated areas to prevent fires and 

explosions. Do not connect or disconnect the power cables or turn the lights on and off in the 

presence of flammable vapours.

 

CAUTION: Dangerous liquids. Read the safety data sheets to know the specific hazards of the 

fluids used. When pouring dangerous liquids, always follow the safety measures provided by the 

liquid manufacturer. Keep dangerous liquids in approved containers and dispose of them in 

compliance with the applicable guidelines.

2.2 - First Aid

In the event of contact with EYES, SKIN, INHALATION or INGESTION, read the SAFETY DATA SHEET 

of the fluid used.

2.3 - Technical specifications

Protective equipment characteristics: 

Wear equipment that is appropriate for the operations to be carried 

out; Wear equipment that is resistant to the products used.  

Personal Protective Equipment to be worn:

Safety footwear

Protective clothing

Protective gloves

Safety goggles

Summary of Contents for Adam Pumps MAT FLOW 3C

Page 1: ...nza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM001 06 2020 rev 06 TECH FLOW 3C 4C MAT FLOW 3C 4C R FLOW 3C 4C ITALIANO lingua origin...

Page 2: ...Soc con Socio Unico or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative The use and m...

Page 3: ...in use Do not blow compressed air through the meter Prevent liquids from drying inside the meter Do not alter or modify the product Alterations or modifications to the product may invalidate the appro...

Page 4: ...install the TECH FLOW MAT FLOW or R FLOW meter as instructed on the back fluid direction arrow The meters can have fluid outlet upwards downwards to the left or to the right 4 GENERAL INDICATIONS 4 1...

Page 5: ...AT FLOW R FLOW meters do not have a suction filter It is advisable to add a suction filter of at least 40 mesh to prevent any residues from interfering with the mechanical parts measuring the fluid To...

Page 6: ...ified or tampered with The product is used in an area with power supply defects voltage changes current phase shift etc The product is used without the supplied suction filter inside or outside the pu...

Page 7: ...indicativo 30 03 2012 Data Approvato 1 di 1 Foglio 2 3 4 6 8 5 7 9 TF3A1 Propriet Componente Adam Pumps 3C DESCRIPTION Q TY 1 TF014N BOTTOM COVER 1 2 TF013N TOP COVER 1 3 TF015G SIDE COVER WITH HOLE 2...

Page 8: ...2000 RESET CAP 1 4 TF044 TF045 NUMERATOR HEAD 1 5 TF069 TF069 MAT FLOW COVER 1 6 OR040 OR040 O RING 130x3 NBR 70 1 7 MA984 MA983 FACEPLATE 1 8 MA071 MA071 MADE IN ITALY LABEL 1 9 13101006 13101006 SCR...

Page 9: ...EAR SHAFT Z 61 11 Z 61 23 1 8 TF102 SHAFT BUSHING 3MM 1 9 TF103 GEAR WHEEL Z61 Z11 1 10 TF104 GEAR WHEEL Z62 1 11 TF105 CONIC PINION SHAFT 1 12 TF106 BUSHING CONIC SHAFT 1 13 TF107 CONIC PINION Z14 1...

Page 10: ...OW MAT FLOW MADE IN Adam Pumps S p A Soc con Socio Unico via della resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com tutte le dime...

Reviews: