General Machine Products (KT), LLC
7.0 Procedure for changing duct clamps
8.0 Procedure for changing cable collets and duct seals in
the air box
Undo the locking screw and
rotate open the duct clamp
housing
Loosen and remove the screw
(1 per insert). Do not lose this
screw; it will be needed for the
replacement clamp.
Remove the duct clamp
Repeat the process for the duct clamp in the other housing half.
To fit the new duct clamp, reverse the disassembly procedure.
For cable collets loosen the screw in the upper
insert. Remove the upper insert from the lower
insert.
Now loosen and remove the screw in the lower
cable seal insert. (Do not lose this screw, it will
be needed for the replacement insert). Re-
move the lower cable collet.
For duct seals loosen and remove the screw.
(Do not lose this screw, it will be needed for the
replacement insert)
Remove the duct seal
Repeat the process for the duct seal in the other
box half
To fit the new inserts, reverse the disas-
sembly procedure.