MCU Interface Selection 

The  connection  between  the  MIFARE  SAM  AV3  and  the  MCU  is  done  by  either  of  the  2   supported  I²C 
interface locations on the Arduino

® 

R3 header. The selection is done by JP3 and JP4, which are placed on 

the corresponding pins. 

 

MIFARE SAM AV3 host interface and VDD selection 

The  MIFARE  SAM  AV3  evaluation  board  offers  two  options  to  interface  with  the  MIFARE  SAM  AV3:  
I²C and ISO7816.  I²C  was  explained earlier  in this  document. For  ISO7816 communication  to supply and 
configure VDD of the MIFARE SAM AV3.  

VDD  is  selected  on  JP9,  the  options  are  permanent  3V3  or  IO6  on  the  Arduino  header.  Permanent  3V3 
means that the MIFARE SAM AV3 will stay in the state it is, until the whole board is power cycled. The ATR 
of the SAM only needs to be retrieved once. Using IO6 as VDD gives the user the possibility to only power 
cycle the MIFARE SAM AV3, therefore having  the option of a reset, without resetting the MCU.  

In case a user wants to access the MIFARE SAM AV3 via the ISO7816 Smartcard interface, a Jumper needs 
to be placed on the ISO7816 header as shown and it is important

 

that

 

in this  case, the VDD selection jumper 

needs  to  be  removed  (set  to  inactive  position  as  shown),  as  the  MIFARE  SAM  AV3  VDD  needs  to  be 
controlled by the ISO7816 interface. 

 

 

 

 

 

Figure 16: SAM AV3 VDD and ISO7816 selection 

Summary of Contents for MIFARE SAM AV3

Page 1: ...l rights reserved Rev 1 0 19 JAN 2022 1 Document information Information Content Keywords MIFARE SAM AV3 evaluation board Direct Mode X mode Satellite Mode S mode I C SPI ISO IEC 7816 CLRC663 family M...

Page 2: ...ickly and easy development secure contactless tag applications The evaluation board therefore incorporates a 13 56 MHz NFC frontend IC of the CLRC663 plus family and an embedded inductive loop antenna...

Page 3: ...d to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipmen...

Page 4: ...nformation provided in this document is subject to legal disclaimers GMMC GmbH 2020 All rights reserved Rev 1 0 19 JAN 2022 4 3 Block Diagram Figure 2 MIFARE SAM AV3 evaluation board Block Diagram Fig...

Page 5: ...o the CLRC663 host interface fordirect communication For SAM communication the user can choose between 2 I C interfaces The default one on IOH1 called I C1 as well as an alternative pinning on AD1 cal...

Page 6: ...663 contactless frontend incorporated on the PCB The digital communication interface SPI and I C from MCU to the CLRC663 can be selected via jumpers The SPI Interface is directly connected to the Ardu...

Page 7: ...hange the MIFARE SAM AV3 in case it has been misconfigured The pullups for theMCU_I C_xxx interface as well as the voltage level divider are placed on the add on board The MIFARE SAM AV3 can be access...

Page 8: ...s with 3 different colors of Jumpers GREEN Configuration of RC663 interfaces YELLOW MCU board I C interface selection RED MIFARE SAM AV3 configuration CLRC663 Interface Mode The CLRC663 NFC reader fro...

Page 9: ...iguration Now the host interface of the CLRC663 is configured as I C and both ADR pins are pulled to low The MIFARE SAM AV3 Master I C interface SAM_I C_xxx can be routed to the host interface of the...

Page 10: ...SO7816 communication to supply and configure VDD of the MIFARE SAM AV3 VDD is selected on JP9 the options are permanent 3V3 or IO6 on the Arduino header Permanent 3V3 means that the MIFARE SAM AV3 wil...

Page 11: ...using the SAM SetConfig command once The command looks like the following Command 80 3C 01 00 01 03 Set Configuration for reader frontend selection Byte Value Meaning CLA 0x80 Class INS 0x3C Instructi...

Page 12: ...e the MIFARE SAM AV3 in X mode See an example configuration below where the SAM can be accessed via the I C1 interface from the MCU and will communicate to the CLRC663 via its host interface configure...

Page 13: ...The MIFARE SAM AV3 is connected via I C1 to the MCU In this way the MCU can control the CLRC663 s LPCD procedure and if a card is detected the SAM can be switched on and take over the control over the...

Page 14: ...______________________________ 4 Figure 10 MIFARE SAM AV3 Add on board _______________________________________________________ 4 Figure 11 related product MIFARE SAM AV3 Add on board _________________...

Page 15: ...odifications in future releases GMMC GmbH does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the conseque...

Reviews: