GMI D1080D Instruction Manual Download Page 3

 

D1080 

- Flammable Liquid Presence Detector Interface Relay Output 

G.M. International ISM0055-9 

Ordering information 

Model:  

D1080D 

Power Bus enclosure 

/B 

 

 

Front Panel and Features 



Input from Zone 0 (Zone 20). 



Dual channel Flammable Liquid Presence Detector Interface Input. 



NPN/PNP 3 wires proximity Detector Input. 



Two SPDT Relay Output Signals. 



Three port isolation, Input/Output/Supply. 



EMC Compatibility to EN61000-6-2, EN61000-6-4. 



In-field programmability by DIP Switch. 



ATEX, IECEx, Russian and Ukrainian Certifications. 



Type Approval Certificate KR for marine applications. 



High Reliability, SMD components. 



High Density, two channels per unit. 



Simplified installation using standard DIN Rail and plug-in terminal blocks. 



250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. 

+ Input Ch 2 for 3 wire Sensor 

Terminal block connections 

HAZARDOUS AREA 

SAFE AREA 

Input Ch 2 for 3 wire Sensor (Collector) 

Input Ch 2 for 3 wire Sensor (Emitter) 

- Input Ch 2 for 3 wire Sensor 

+ Input Ch 1 for 3 wire Sensor 

Input Ch 1 for 3 wire Sensor (Collector) 

Input Ch 1 for 3 wire Sensor (Emitter) 

- Input Ch 1 for 3 wire Sensor 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

Output Ch1 Common 

1

 

Output Ch1 Relay Normally Opened (NO) 

2

 

+ Power Supply 24 Vdc 

3

 

- Power Supply 24 Vdc 

4

 

Output Ch2 Common 

5

 

Output Ch2 Relay Normally Opened (NO) 

6

 

Output Ch2 Relay Normally Closed (NC) 

7

 

Output Ch1 Relay Normally Closed (NC) 

8

 

Summary of Contents for D1080D

Page 1: ...D1080 Flammable Liquid Presence Detector Interface Relay Output ISM0055 9 D1080D INSTRUCTION MANUAL Flammable Liquid Presence Detector Interface Relay Output DIN Rail Model D1080D ...

Page 2: ...d electrical apparatus Uo Voc 15 8 V Io Isc 109 mA Po Po 428 mW at terminals 13 16 9 12 Uo Voc 15 8 V Io Isc 13 mA Po Po 51 mW at terminals 14 16 13 15 10 12 9 11 Um 250 Vrms 20 C Ta 60 C Approvals DMT 01 ATEX E 042 X conforms to EN60079 0 EN60079 11 EN60079 26 EN61241 0 EN61241 11 IECEx BVS 07 0027X conforms to IEC60079 0 IEC60079 11 IEC60079 26 IEC61241 0 IEC61241 11 Russia according to GOST 12 ...

Page 3: ...MD components High Density two channels per unit Simplified installation using standard DIN Rail and plug in terminal blocks 250 Vrms Um max voltage allowed to the instruments associated with the barrier Input Ch 2 for 3 wire Sensor Terminal block connections HAZARDOUS AREA SAFE AREA Input Ch 2 for 3 wire Sensor Collector Input Ch 2 for 3 wire Sensor Emitter Input Ch 2 for 3 wire Sensor Input Ch 1...

Page 4: ... 9 12 Io Isc 13 mA Ch1 Ch2 14 16 13 15 10 12 9 11 Po Po 428 mW Ch1 Ch2 13 16 9 12 Po Po 51 mW Ch1 Ch2 14 16 13 15 10 12 9 11 Ii Imax Pi Pi D1080 Associated Apparatus Parameters Ci Ci device C cable Li Li device L cable Li Ri device and L cable R cable II A B Co Ca 478 nF Co Ca 2 88 µF Co Ca 11 6 µF IIB C IIA D IIC A B Co Ca 478 nF Co Ca 2 88 µF Co Ca 11 6 µF IIB C IIA D IIC A B Lo La 3 mH Lo La 12...

Page 5: ...tput G M International ISM0055 9 Function Diagram HAZARDOUS AREA ZONE 0 ZONE 20 GROUP IIC SAFE AREA MODEL D1080D 3 4 8 NC 2 NO 1 COM Supply 24 Vdc Out 1 7 NC 6 NO 5 COM Out 2 13 14 15 In 1 3 wire Sensor 16 3 wire Sensor 9 10 11 In 2 3 wire Sensor 12 3 wire Sensor ...

Page 6: ...more than 250 Vrms or Vdc Control Equipment Safe Area 13 14 1 2 Power Supply 3 4 16 15 8 Control Equipment 7 6 5 12 Intrinsically Safe Equipment 11 10 9 Installation D1080 is a liquid presence detector interfaces housed in a plastic enclosure suitable for installation on T35 DIN Rail according to EN50022 D1080 unit can be mounted with any orientation over the entire ambient temperature range see s...

Page 7: ...nfiguration 1 2 3 4 ON Switch positions Trip Current Level Ch2 Ch1 A configuration DIP Switch is located on component side of pcb This switch allows the configuration of input output relationship and the trip current levels Channel IN OUT Operation NO ND or NC NE NO NE or NC ND Dip switch Configuration Summary Table 1 SW1 OFF ON 2 SW2 OFF ON Trip Current Level 8 mA Sensor 0 to 5 mA 11 mA Sensor 3 ...

Reviews: