background image

 

3

1- ON/OFF 

When the power is on, press ON/OFF to start or stop the machine. 

2- MODE 

Press MODE to choose three operation modes: COOL, FAN or DRAIN.   

COOL:          I  is  the  cooling  figure.  The  water  pump  will  run  for  three  minutes  first,  water  is 

evenly distributed onto cooling pads, and then the fan starts. Press ▲▼to adjust airflow from 1

-6. 

FAN:        is  the  fan  figure.  At  this  moment,  the  water  pump  does  not  work,  only  fan  delivers 

airflow. Press ▲▼to adjust speed from 1

-6. 

DRAIN:        is the drain figure. When draining, the arrowhead runs. 

3- TIME SETTING 

Press TIME for the first time, you can set time of cooler start, adjust its starting time by pressing 

▲▼;  Press  TIME  for  the  second  time,  you  can  set  time  of  cooler  stopping,  adjust  its  stopping 
time by pressing ▲▼. Press TIME until the number flickers for three seconds, the time setting of 

cooler starting and stopping is cancelled. 

4- CLOCK 

CLOCK

 is for clock setting. Adjust clock by pressing ▲▼.

 

5-

 

SWING 

Not used.   

 
GMC EVAPORATIVE AIR COOLER – MAINTENANCE                               

1-  If  the  cooler  is  used  in  very  sandy  and  dusty  areas,  cooling  pads  should  be  often  cleaned  to 

ensure cooling efficiency. When cleaning, do not use high pressure water, hot water (up to 40 

or chemical detergents. 

2- Clean cooler water sump every half year to keep the cooling air clean and fresh. 

3- Drain the water from water sump after the first 24 hours of new cooler operation, the odor will 

not smell any more. 

4- To  prevent  the  cooler  freezing  and  worms,  do  shut  up  water  supply  and  keep  the  water  sump 

dry  if  the  cooler  will  be  leaved  unused  for  a  long  time.  Cover  it  in  sandy  or  snowy  weather  if 

necessary. 

5- Make sure that all the cooler screws are not loose to prevent cooler from shaking severely when 

its operation. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GMCAB18

Page 1: ...ORATIVE AIR COOLER IMPORTANT NOTES 1 After turning on the cooler be sure that water pump should work for 3 minutes first let water evenly distributed onto cooling pads then start fan and adjust fan speed This step is very important to prevent water drop from splashing on motor and helpful to prolong motor lifespan 2 Ensure the single phase voltage is 5 Too low or high voltage may cause damage to c...

Page 2: ...rol system LCD display GMC EVAPORATIVE AIR COOLER INSTALLATION TIPS 1 The supporting frame must be strong and firm enough to bear the weight of cooler and maintenance technician 2 The cooler installation must be horizontal not acclivitous otherwise water will overflow from the cooler water sump 3 Ensure that drainage elbow is installed properly keep it from cooler duct to avoid the water drops go ...

Page 3: ... until the number flickers for three seconds the time setting of cooler starting and stopping is cancelled 4 CLOCK CLOCK is for clock setting Adjust clock by pressing 5 SWING Not used GMC EVAPORATIVE AIR COOLER MAINTENANCE 1 If the cooler is used in very sandy and dusty areas cooling pads should be often cleaned to ensure cooling efficiency When cleaning do not use high pressure water hot water up...

Page 4: ...is too low 1 Increase water pipe pressure 2 Adjust float valve make water level 7 10 CM high 3 Replace water inlet valve 6 Fan fails to deliver airflow 1 Check if motor is damaged 2 Check if fan blades are stuck 3 Check if LCD main control board is damaged 1 Replace motor 2 Adjust fan blades position 3 Replace contactor 4 Replace capacitor 5 Replace LCD main control board 7 Cooler fails to deliver...

Page 5: ...horizontally 3 Replace sealing ring of float valve 4 Replace float valve 11 Water drops splash from cooler 1 Check if inner water pipes fall from joints 2 Check if elbows fall from joints 3 Check if cooling pads are blocked 1 Fix inner water pipes again 2 Fix elbows again 3 Clean cooling pads 12 Water drops splash from duct 1 Check if drainage outlet is installed properly 1 Extend drainage outlet ...

Page 6: ...6 ...