28
GOSSEN-METRAWATT
11
Technical Data
* METRATESTER
â
4 only
Operational Measurements
Overload Capacity
Intrinsic and Service Error
* METRATESTER
â
4 only
Meas. Quantity
Measuring Range
Resolution
U
NO-LOAD
R
i
I
K
I
N
PE Resistance
0 ... 19.99
W
10 m
W
< 20 V
-
—
> 200 mA
Insulation
Resistance
0 ... 1.999 M
W
*
0 ... 19.99 M
W
1 k
W
10 k
W
600 V
-
600 V
-
ca. 100
k
W
< 10 mA
> 1 mA
> 1 mA
Equivalent
Leak. Current
0 ... 19.99 mA
~
10
m
A
28 V
~
2 k
W
< 20 mA
—
Confirmation of
absence of voltage
with current
measurement
(contact or leak-
age current)
0
¼
1.999 mA
~
1
m
A
2 k
W
Residual Current
(METRATESTER
â
5/
5-F
only
)
0.01
¼
19.99 mA ~
10
m
A
Meas. Quantity
Measuring Range
Resolution
Mains Voltage
207 ... 253 V ~
1 V
Load current at mains outlet
0 ... 16.00 A ~
10 mA
Load current at mains outlet, residual current
19 A, 5 min.
All other measuring quantities
250 V
continuous
Meas. Quantity
Intrinsic Error
Service Error
Protective Conductor Resistance
±
(2.5 % of rdg. + 2 D)
±
(10 % + 5 D)
Insulation Resistance
0 ... 1.999 M
W
*
0 ... 19.99 M
W
±
(2.5 % of rdg. + 2 D)
±
(2.5 % of rdg. + 2 D)
±
(10 % of rdg. + 5 D)
±
(10 % of rdg. + 5 D)
Equivalent Leakage Current
±
(2.5 % of rdg. + 2 D)
±
(10 % of rdg. + 5 D)
Confirmation of absence of voltage with
current measurement (contact current)
±
(2.5 % of rdg. + 2 D)
±
(10 % of rdg. + 5 D)
Residual Current
(
METRATESTER
â
5/5-F only)
±
(4 % of rdg. + 5 D)
±
(10 % of rdg. + 5 D)
Mains Voltage
±
(2.5 % of rdg. + 2 D)
±
(10 % of rdg. + 5 D)
Load current at mains outlet
±
(2.5 % of rdg. + 2 D)
±
(10 % of rdg. + 5 D)