Chevrolet/GMC 2.8L Duramax Diesel Engine Supplement (GMNA-Localizing-
U.S./Canada-13336155) - 2020 - CRC - 5/6/19
60
Driving and Operating
Programmable
Parameters
Factory Setting
Minimum Value
Maximum Value
Engine Speed Tap Step
100 rpm
4 rpm
500 rpm
Engine Speed Ramp Rate
150 rpm
4 rpm
150 rpm
Maximum Vehicle Speed
94 km/h (58 mph)
30 km/h (19 mph)
94 km/h (58 mph)
Minimum Remote
Potentiometer Threshold
2%
0%
50%
Maximum Remote
Potentiometer Threshold
95%
50%
100%
Remote Set Switch
Transition to Low Voltage
(<33% of Ignition Voltage)
SET SPEED 1
STANDBY SPEED, SET SPEED 1, or SET SPEED 2
Remote Set Switch
Transition to Open State
(>33% of Ignition, and
<67% of Ignition Voltage)
PTO STANDBY
STANDBY SPEED, SET SPEED 1, or SET SPEED 2
Remote Set Switch
Transition to High Voltage
(>67% of Ignition Voltage)
SET SPEED 2
STANDBY SPEED, SET SPEED 1, or SET SPEED 2
Horn Chirps during a
Remote Start Event
ENABLED
DISABLED
ENABLED
Personalization Menu
ENABLED
DISABLED
ENABLED