About eSATA

• eSATA is an external interface technology that grew from the internal SATA I interface.

• The GT 062E’s eSATA port supports speeds up to 3 Gb/sec (300 MB/sec), much faster than FireWire 400 or 

FireWire 800.

• Shielded eSATA cables up to 2 meters in length are available. 

• eSATA cables are different than SATA I cables, they are shielded and cannot be used with internal SATA I 

connectors.

• eSATA uses a “point-to-point” connection, therefore each eSATA drive needs to be connected to its own 

eSATA port.

• Most computers do not have built-in eSATA, so you’ll need a PCI card to connect your drive with eSATA. 

Glyph sells various eSATA cards.

About FireWire 800

• FireWire 800 supports speeds up to 800 Mb/sec, twice as fast as FireWire 400. 

• If your computer does not have built-in FireWire 800, you’ll need a PCI card to achieve a true FireWire 800 

connection.

• Most 800 ports are Bi-Lingual, which means they speak both FireWire 400 and FireWire 800. 

• If you connect a 400 device to an 800 device, you will be running at 400 speed maximum. 

• FireWire is forward-compatible and back-compatible, but the bus always runs at the speed of the slowest 

link. 

• Beta cables are used to connect 800 devices to 800 devices. 

• Bi-Lingual cables are available to connect 400 devices to 800 devices. 

• Bi-Lingual cables have a 9-pin Bi-Lingual connector at one end and a 4-pin or 6-pin FireWire 400 connector 

at the other end 

Frequently Asked Questions

Q: How do I know if I have the correct version of Glyph Manager?

To get the latest version of Glyph Manager, go to the support section of www.glyphtech.com and download 

the version for your operating system.

Q: Do I need to have Glyph Manager installed to use the GT 062E?

No, Glyph Manager is used for configuration and monitoring only. It is required to change drive configura-

tion or monitor drive health. It is not necessary to install Glyph Manager, but it is recommended.

Q: Do I need any drivers to use the GT 062E?

No drivers are required to read and write to the drive using eSATA, FireWire or USB. A driver is required to use 

Glyph Manager to change configuration or monitor drive health. All necessary drivers are installed as part of 

the Glyph Manager installation.

Q: Do I need RAID software?

Summary of Contents for GT 062E

Page 1: ...delivered Additional rights and obligations regarding this document and its contents may be defined by a separate written agreement with GLYPH and if so such separate written agreement shall be contr...

Page 2: ...cessories are packaged in a sturdy shipping container Please inspect the con tainer for evidence of shipping damage and mishandling If the container is damaged file a report with the carrier or dealer...

Page 3: ...signed to increase the performance and data throughput of the drive system The GT 062E s built in RAID controller splits each piece of data across both of the drives in segments and distributes the I...

Page 4: ...n either purchase an eSATA or FireWire adapter card recommended or use the USB 2 0 port on the back of the GT 062E Front panel LED The GT 062E front panel has a single bi color LED The LED will displa...

Page 5: ...nstalled in the MAC OS X the left hand pane of the Glyph Manager screen displays general informa tion regarding all Glyph enclosures that can be monitored GT 062 GT 062E Each will be displayed with a...

Page 6: ...ed as well as the temperature of the bridge the internal circuits Drive temperatures over 68 C is detrimental to continued proper operation of the drives Status Indicates array functionality A properl...

Page 7: ...but that the data is being rebuilt Under normal operation this will not occur Occasionally after an improper shutdown for example if the unit was powered down while data was being written to the disk...

Page 8: ...g so To change the drive mode follow these steps 1 Install Glyph Manager software 2 Connect the GT 062E via FireWire or USB and open Glyph Manager software If you have more than one GT 062E connected...

Page 9: ...uration has changed After a few seconds the system will update and Glyph Manager will dis play the new drive configuration Click OK in this window 7 The next window prompts you to finalize the new con...

Page 10: ...ll start automatically and will display a Glyph icon in the lower right corner of the system tray Right clicking on this icon and then selecting Show will invoke Glyph Manager to the screen NOTE With...

Page 11: ...rite speeds to the Glyph drive This setting only applies when us ing FireWire 800 The default Windows settings for FireWire connected drives can reduce your Glyph drive performance by as much as 90 Th...

Page 12: ...lled setup exe and then accept the End User Licensing Agreement Next accept or change the target install folder The installation will create a Start Menu folder by default Check the box marked Don t c...

Page 13: ...g Instructions 1 From your computer s task bar go to Start Programs MS DOS Prompt 2 At the prompt type fdisk and press Enter You ll see a long message about disk support 3 Enter Y type Y and press Ent...

Page 14: ...r the drive This name will identify the drive on the desktop 6 Click the Install Mac OS 9 Disk Driver button if you would like your drive to be compatible with OS 9 7 Click the Erase button to erase y...

Page 15: ...atibility Mac OS 8 6 9 X 10 X Microsoft Windows 98SE ME 2000 XP Vista 7 Modern Unix based Linux or BSD Warranty 3 Years 2 Years Free Basic Data Recovery 1 Year Overnight Advance Replacement in USA Con...

Page 16: ...g at 400 speed maximum FireWire is forward compatible and back compatible but the bus always runs at the speed of the slowest link Beta cables are used to connect 800 devices to 800 devices Bi Lingual...

Page 17: ...es between FireWire 800 and FireWire 400 Speed and Protocol FireWire 800 has a max transfer rate of 800 Mb sec about 100 MB sec peak FireWire 400 has a max transfer rate of 400 Mb sec about 50 MB sec...

Reviews: