SAFETY RECOMMANDATIONS 

 
READ CAREFULLY 
1. The unit does not provide protection from lightning and surge. For outdoor installation use outdoor 
plastic case safety approve according UL 50. Additional provide protection from lightning and over voltage 
according National code. 
 
2

Be sure the use of this product is allowed in the country and in the environment required. The use of this 

product may be dangerous and has to be avoided in the following areas: 
Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, 
etc. Where there is risk of explosion such as gasoline stations, oil refineries, etc It is responsibility of the 
user to enforce the country regulation and the specific environment regulation. Do not disassemble the 
product; any mark of tampering will compromise the warranty validity. We recommend following the 
instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied 
with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention 
regulations. The product has to be handled with care, avoiding any contact with the pins because 
electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, 
checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power 
saving mode. The system integrator is responsible of the functioning of the final product; therefore, care 
has to be taken to the external components of the unit, as well as of any project or installation issue, 
because the risk of disturbing the GSM network or external devices or having impact on the security. Should 
there be any doubt, please refer to the technical documentation and the regulations in force. Every unit has 
to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with 
care in order to avoid any interference with other electronic devices and has to guarantee a minimum 
distance from the body (20 cm). In case of this requirement cannot be satisfied, the system integrator has to 
assess the final product against the SAR regulation. The European Community provides some Directives for 
the electronic equipments introduced on the market. All the relevant information’s are available on the 
European Community website: 

http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm 

The text of the Directive 99/05 regarding telecommunication equipments is available, while the 
applicable Directives (Low Voltage and EMC) are available at: 

http://europa.eu.int/comm/enterprise/electr_equipment/index_en.htm

 

 

 
 

7.

 

2-Year Limited Warranty 

Glyn warrants, to the original purchaser, that this equipment shall be free of defects in materials and 
workmanship for a period of two (2) years. 
This warranty does not apply if the product has been misused or has been damaged by accident, abuse, 
misuse, or misapplication or if it has been modified without permission. 
 

 
 
 
 
 
 
 
 

Summary of Contents for EZ864 PY

Page 1: ...1 EZ864 PY Telit Cellular GSM UMTS Engine Hardware guide for EZ864 PY Terminal version 3 2 Date 01 09 2011...

Page 2: ...4 QUAD V2 Frequency bands Quad band GSM 850 900 1800 1900MHz Power supply Single supply voltage 5V to 30V Operating temperature 20 C to 65 C ambient temperature Physical Dimensions 83mm x 64m x 33m We...

Page 3: ...terface and antennas 1 SMA connector female for GSM antenna 2 4 pole 3mm Micro Mate N LOK connector for power supply 3 SIM card holder 4 9 pole female SUB D plug for RS 232 5 Led Cellular and Led Powe...

Page 4: ...and typical accessories Level Shifter RS232 SMA Antenna GSM SIM 4 pin 9 pin D Type PC Com RS232 Input power and GND 3 GPIO inputs 5 24V Power 1 ADC 1 Pin GND GROUND Input Power 5 30v UART 1 GC864 QUAD...

Page 5: ...4 PY at a 24V power supply system for vehicles The power supply must be compliant with the EN60950 guidelines Pin Signal name Use 1 POWER Input Power supply range 5 30V 2 3 GND Ground 4 Pin assignment...

Page 6: ...nterface and it is managed by AT commands according to the GSM 07 07 and 07 05 specification and the supported commands are listed in the AT Commands Reference Guide Pin assignment RS 232 D Type 9 fem...

Page 7: ...plays the network status of the EZ864 PY Red LED status Device Status permanently on a call is active fast interrupt sequence period 0 5s Ton 1s Net search Not registered turning off slow interrupt se...

Page 8: ...l The power supply recommended to be any safety approved power supply certified IEC 60950 1 or EN 60950 1 or UL 60950 1 with limited output current up to 2A The type of the receptacle assembled on the...

Page 9: ...r saving mode The system integrator is responsible of the functioning of the final product therefore care has to be taken to the external components of the unit as well as of any project or installati...

Page 10: ...rence standard s Radio Note test only for GC864 module Number Market Standard Procedure 1 Europe EN 301 511 V9 0 2 Spurious Emissions testing EMC Number Market Standard Procedure 2 Europe EN 301 489 7...

Reviews: