background image

GLX LED STAGE 4 MANUAL 

 

 

 

Technical specifications 

Power supply:   

 

 

 

 

220-250V AC, 50-60 Hz~ 

Power consumption: 

 

 

 

 

50W 

Number of DMX channels: 

 

 

 

15 

DMX-512 connection:   

 

 

 

3 pin XLR 

Number of 10mm LEDs:  

 

 

 

432 

Beam angle: 

 

 

 

 

 

25º 

Sound-control:   

 

 

 

 

Via built-in microphone 

Maximum ambient temperature Ta: 

 

 

45ºC 

Maximum housing temperature TB (steady state) 

60ºC 

Min.distance from flammable surfaces:   

 

0.50m 

Min.distance to lighted object:   

 

 

0.10m 

Fuse:   

 

 

 

 

 

F 2A, 250V 

Dimensions (LxWxH):   

 

 

 

1110 X 55 X 295 

Weight:  

 

 

 

 

 

8kg 

 
Channels 

Channel 1 - 

Internal

 

programs, auto mode and sound controlled mode

 

Value   

 

Function 

000-009 

 

Off 

010-029 

 

Program 1 

030-049 

 

Program 2 

050-059 

 

Program 3 

070-089 

 

Program 4 

090-109 

 

Program 5 

110-129 

 

Program 6 

130-149 

 

Program 7 

150-169 

 

Program 8 

170-189 

 

Program 9 

190-209 

 

Program 10 

210-229 

 

Program 11 

230-249 

 

Auto Mode: Internal Programs 

250-255 

 

Sound controlled Mode 

 
Channel 2 - 

Master Dimmer 

 

 

 

Channel 3 - 

Strobe

 

Value   

Function 

 

 

 

Value   

Function 

000-009 

Off 

 

 

 

 

000-009 

Off 

010-255 

Dimming from 0 – 100%  

 

010-255 

Flash with increasing speed 

 
Channel 4 – 

spot 1

 

RED 

 

 

 

Channel 5 – 

spot 1

 

GREEN

 

Value   

Function 

 

 

 

Value   

Function 

000-255 

Dimming from 0 - 100 %  

 

000-255 

Dimming from 0 - 100 % 

 
Channel 6 – 

spot 1

 

BLUE 

 

 

 

Channel 7 – 

spot 2

 

RED

 

Value   

Function 

 

 

 

Value   

Function 

000-255 

Dimming from 0 - 100 %  

 

000-255  

Dimming from 0 - 100 % 

 
Channel 8 – 

spot 2

 

GREEN 

 

 

 

Channel 9 –  

spot 2

 

BLUE

 

Value   

Function 

 

 

 

Value   

Function 

000-255  

Dimming from 0 - 100 %  

 

000-255  

Dimming from 0 - 100 % 

Summary of Contents for GLS-4 LED STAGE 4

Page 1: ...GLX LED STAGE 4 MANUAL 1 GLS 4 LED STAGE 4 owners manual ...

Page 2: ...d Please note for overhead rigging in public or industrial areas a series of safety instructions have to be followed that this manual can only give in part Main connection The device must only be connected in compliance with the IEC standards The electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30mA Lighting effects must never be connected t...

Page 3: ...kout To discontinue operation of the footswitch press pedals 1 and 4 simultaneously then release both pedals simultaneously Cleaning and maintenance Make sure that 1 All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations of the housings fixations and installation spots ceiling suspension trussing ...

Page 4: ...049 Program 2 050 059 Program 3 070 089 Program 4 090 109 Program 5 110 129 Program 6 130 149 Program 7 150 169 Program 8 170 189 Program 9 190 209 Program 10 210 229 Program 11 230 249 Auto Mode Internal Programs 250 255 Sound controlled Mode Channel 2 Master Dimmer Channel 3 Strobe Value Function Value Function 000 009 Off 000 009 Off 010 255 Dimming from 0 100 010 255 Flash with increasing spee...

Page 5: ...55 Dimming from 0 100 000 255 Dimming from 0 100 Channel 12 spot 3 BLUE Channel 13 spot 4 RED Value Function Value Function 000 255 Dimming from 0 100 000 255 Dimming from 0 100 Channel 14 spot 4 GREEN Channel 15 spot 4 BLUE Value Function Value Function 000 255 Dimming from 0 100 000 255 Dimming from 0 100 ...

Reviews: