background image

311-4141100-008 

Version 2.0

2017/03

BLOOD GLUCOSE 

MONITORING SYSTEM

OWNER’S BOOKLET

(TD-4141)

Dear owner of GlucoRx Nexus mini ultra Blood Glucose Monitoring System,
The system consists of three main products: the meter, test strips and control solution. 
These products have been designed, tested, and proven to work together as a system to 
produce accurate blood glucose test results. Only use GlucoRx Nexus test strips and control 
solutions with the GlucoRx Nexus mini ultra Blood Glucose Monitoring System.  

Intended Use

This system is intended for external use (

in vitro

 diagnostic use) only. It is used for the 

quantitative measurement of glucose in samples of fresh capillary whole blood taken from 
the palm, forearm, or fingers. It is not intended to diagnose or screen for diabetes mellitus, 
or to be used on newborn babies.

Professionals may test with capillary and venous blood sample; home use is limited to 
capillary whole blood testing.

This system provides you with plasma equivalent results.

Read Before Use

The meter will turn off automatically after 120 seconds without any action, or you can 
press and hold 

 and 

 to turn off the meter.

NOTE

IMPORTANT SAFETY INSTRUCTIONS

APPEARANCE AND KEY FUNCTIONS OF THE METER

With the hour flashing, press 

 until the correct hour 

appears. Press 

.

With the minute flashing, press 

 until the correct 

minute appears. Press 

.

STEP 3. Set the hour and minute

Blood Drop Symbol

1

Measuring Mode

2

AC/PC Indicator

3

Error Message

6

Test Result

5

4

Memory Symbol

Low Battery Symbol

7

Alarm Symbol 

8

Time Display

9

Measurement Unit

10

METER DISPLAY

2

1

3

4

5

10

7

6

8

9

STEP 2. Setting the time format.

Press 

 to select the desired time format -- 12h or 24h. 

Press 

.

STEP 2. Apply control solution

STEP 3. Read and compare the results

Shake the control solution vial thoroughly before use. Squeeze 
out a drop and wipe it off, then squeeze out another drop and 
place it on the tip of the vial cap. Hold the meter to move the 
absorbent hole of the test strip to touch the drop. Once the 
confirmation window fills completely, the meter will begin 
counting down. To avoid contaminating the control solution, 
do not directly apply control solution onto a strip.

After the meter counts to 0, the result of the control solution 
test will appear. Compare the result with the range printed on 
your test strip vial. The result should fall within this range.

Out-of-range results

 

If you continue to have test results falling outside the range printed on the test strip vial, 
your meter and/or strips may not be working properly. Do 

NOT

 test your blood. Contact 

GlucoRx Customer Services on 01483-755133.

Every time you perform a control solution test you must enter “QC” test mode so that 
the test result will not be stored in the meter memory.

CAUTION 

STEP 3. Apply blood sample

Wipe the first drop off and obtain a drop of blood of at least 0.5 µL using the GlucoRx 
lancing device. Use the clear cap for sites other than fingers and refer to the strip package 
insert for more details.

Preparing the Lancing Device for Blood Testing 

Please follow the instructions in the lancing device insert for collecting a blood sample.
Never share a lancet of the lancing device. GlucoRx Lancing device is for 

self-use only.

STEP 1. Insert the test strip to turn on the meter

Wait for the meter to display “

   

 ”.

STEP 2. Select the appropriate measuring mode by pressing 

For selecting the measurement mode, please refer to the “FOUR MEASURING MODES”.

TESTING YOUR BLOOD

STEP1. Insert test strip

Insert a test strip into the test slot with the contact bars end first and facing up. (Contact 
bars must be inserted all the way into the meter or you may get an inaccurate test result.) 
The meter turns on automatically and displays the following in sequence:

When the “     “ symbol appears on the display, press 

 and “QC” will appear on the display. 

When the “QC” sign is displayed, the meter will not store your test result in the memory. If 
you decide not to perform a control solution test, press 

 again and the “QC” sign will 

disappear. 

Display Screen with White Backlight

2

Down Button (

)

3

Battery Compartment

6

Up Button (

)

4

Test Strip Slot / Strip Cable Slot

5

Insert test strip here to turn the 
meter on for testing.

Test Strip Ejector

1

Eject the used strip by pushing 
up this button.

6

1

2

3

4

5

Your system measures the amount of sugar (glucose) in whole blood. Blood is applied to 
the absorbent hole on the test strip and is automatically drawn into the reaction cell where 
the reaction takes place.

The test strip consists of the following parts:

Contact Bars

Insert this end of the test strip into the meter.
Push it in firmly until it will go no further.

Test Strip Handle

Hold this part to insert the test strip into the slot.

Absorbent Hole

Apply a drop of blood here.
The blood will be automatically absorbed.

Confirmation Window

This is where you confirm if enough blood has been 
applied to the absorbent hole in the strip.

GlucoRx Nexus TEST STRIPS

STEP 1. Set the date

Start with the meter off (no test strip inserted). 

Press and hold 

 and 

 at the same time.

With the year flashing, press 

 until the correct year 

appears. Press 

.

With the month flashing, press 

 until the correct month 

appears. Press 

.

With the day flashing, press 

 until the correct day appears. 

Press 

.

SETTING THE METER 

Date obtained:                 /                 /                Serial No:

Date obtained:                 /                 /                Serial No:

WARRANTY REGISTRATION CARD

WARRANTY CERTIFICATE

[ Dealer’s Portion ]

[ Owner’s Portion ]

Product Name: 

 

 

Owner’s Name:

 

Address: 

 

 

Tel No: (M)

 

 

(H)

  

 

(W)

Email:

 

Date of Birth: 

 

 

Gender:  

 

M   

 

F

Blood glucose testing frequency:
Insulin dependent?

GP Surgery name and Address:

 

GP Surgery name and Address:

Day

Day

Month

Month

Year

Year

*IMPORTANT: To qualify for the warranty, please fill in this card and mail to us within 6 months from date product obtained.

*NOTE: Please produce this card for warranty service.

Product Name: 

 

 

Owner’s Name:

 

Address: 

 

 

Tel No: (M)

 

 

(H)

  

 

(W)

Email:

 

Date of Birth: 

 

 

Gender:  

 

M   

 

F

Blood glucose testing frequency:
Insulin dependent?

 

YEAR WARRANTY

STEP 4. Setting the buzzer beep

Press 

 to switch between buzzer beep on or off. 

Press 

.  

STEP 5. Setting the reminder alarm

Your meter has four reminder alarms. The meter will 
display “OFF”, “AL1” and “      ”. If you don’t want to set 
an alarm, press 

 to select “OFF”, and then press 

 to 

skip this step. Or select “On” and press 

 to proceed.

With the hour/minute flashing in sequence, press 

 

to select the correct hour/minute. Press 

 and go to 

the next alarm setting.

Our control solution contains a known amount of glucose that reacts with test strips. By 
comparing the result of your control solution test with the expected range printed on the 
test strip vial label, you can check that the meter and test strips are working together as a 
system and that you are performing the test correctly. It is very important that you perform 
this simple check routinely to make sure you get accurate results.

HOW TO PERFORM A CONTROL SOLUTION TEST

CHECKING THE SYSTEM WITH CONTROL SOLUTION

1. Start with the meter switched off. Insert a test strip to turn on the meter. The screen will 
display “

   

 ”.

The meter provides you with four modes for measuring: General, AC, PC and QC. 

You can switch between each mode by:

MODES

USE WHEN

General 

AC 

PC

QC

any time of day, regardless of time since last meal

no food intake for at least 8 hours

2 hours after a meal

testing with the control solution

THE FOUR MEASURING MODES 

2. Press 

 to switch between General, AC, PC and QC mode.

Reviews: