background image

In

s

tr

u

c

ti

o

n

 M

a

n

u

a

 
 
 
 
 
 
 

           

 

 

from software version 1.24/30  
(Instruction version 1.5)

 

 

e-mail: [email protected] 

Internet: http://www.glp.de

Summary of Contents for Impression 120RZ RGB

Page 1: ...Instruction Manual from software version 1 24 30 Instruction version 1 5 e mail service glp de Internet http www glp de...

Page 2: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 5 from software version 1 24 30 2 Notes...

Page 3: ...unting on the floor upright 7 2 1 2 Mounting in hanging position head down 8 2 1 3 Mounting in a sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 10 3 The...

Page 4: ...ng head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side 2 7 8...

Page 5: ...ts Opening the fixture will void the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attenti...

Page 6: ...in this manual 11 Use only original spare parts Any structural modification on the system will terminate all warranty claims 12 Please keep this instruction manual for future reference 2 Preparation...

Page 7: ...elease fasteners front side of the fixture 2 1 1 Mounting on the floor upright To operate the I IM MP PR RE ES SS SI IO ON N in an upright position please use the dedicated floor stand which ships wit...

Page 8: ...te the I IM MP PR RE ES SS SI IO ON N in a sideways position please use an additional mounting bar available from GLP or one of their agents This mounting bar is fixed via the two camlock quick releas...

Page 9: ...attached to the fixture by threading it through one of the two holes provided on the base of the fixture Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting...

Page 10: ...he entry and go back to the main menu Mode Down Enter Up DOWN UP MODE ENTER Level1 Level 2 Level 3 Level 4 Remark DMX Start Address 001 Set the DMX start address Special Manual DMX Manual control of a...

Page 11: ...ction diagnose Anz Ti0 Int Err Internal data and function diagnose PFC Voltage Show the present PFC voltage Pos Feed Tilt Delta Internal data and function diagnose Temperature Arm Displays the arm tem...

Page 12: ...ed DMX Mode Compressed Fixture works in Compressed mode see also sectiion 4 Normal Fixture works in Normal mode see also section 4 High Resolution Fixture works in High Resolution mode see also sectio...

Page 13: ...channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300 1 5 s 0 255 00 FF 0 100 4 Til...

Page 14: ...6 Mode ON 40 43 28 2B 16 17 K2 Mode OFF 6 Mode OFF 44 47 2C 2F 17 5 19 White Mode ON 6 Mode ON 48 51 30 33 19 20 White Mode OFF 6 Mode OFF 52 55 34 37 20 5 21 RGB value spreading ON 6 Mode ON 56 59 3...

Page 15: ...possibility exists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximu...

Page 16: ...38 40 5 White CTO Color temperature 3200K 104 111 68 6F 41 43 5 White Color temperature 5600K 112 119 70 77 44 46 5 White CTB Color temperature 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 2 128 8...

Page 17: ...slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 E...

Page 18: ...r settings will remain unchanged Additional Display Indications As a default you ll find the following additional information in the first row of the LCD display XX X XX 06 600Hz 12 1200Hz N Normal Mo...

Page 19: ...nment Hence no specific guidelines can be given The cleaning intervals given below are suggestions based on practical experience We suggest that you start with these and develop your own maintenance s...

Page 20: ...42x green LEDs 36x blue LEDs 42x red LEDs Wavelength optimized for maximum presentable color space Optical System High efficiency collimator cluster Motorized optical lens plate with a range of 10 26...

Page 21: ...ersion 1 Internet 1 L LED Class 2M 5 M Maintenance 19 Max Power Mode 15 Menu Field 10 Micro fuse 9 Mode key 10 Mounting 6 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting on the...

Page 22: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 5 from software version 1 24 30 22...

Reviews: