German Light Products®
Fusion Par FP7 User Manual Rev. A
27
9.
Control menu layout
Menus
Notes
DMX
Address
1
- 512
Enter DMX address
Mode
Stand-8
Select DMX control mode
6-CH
5-CH
RGBW-4
RGB – 3
Easy - 2
No DMX
Shut off
Blackout when no DMX
signal is received
Hold
Hold current scene when
no DMX signal is received
Play P1
Play stored stand-alone
program 1, 2 or 3 when no
DMX signal is received
Play P2
Play P3
DMX Live
Refresh XXX
Hz
Display current DMX signal
refresh rate
Color
Red
Green
Blue
White
Shutter
Dimmer
CTO
0 - 255
0 - 255
0 – 255
0 – 255
0 – 255
0 – 255
0 – 255
0 - 255
Display DMX values being
received for each effect
Personal
D Curve
Linear
Select dimming curve
Theat
Square
Inv Sq
D Speed
Fast
Dimmer optimized for
speed
Smooth
Dimmer optimized for
smoothness
PWM
600 Hz
Select LEDs’ PWM
frequency
1200 Hz
2000 Hz
2400 Hz
6000 Hz
Mic
Off
Audio trigger disabled
On
Audio trigger active
Mic Sens
Normal
Set audio trigger
microphone sensitivity
High
Low
Summary of Contents for Fusion Par FP7