Glow-worm Ultracom sxi Instructions For Use Manual Download Page 3

www.glow-worm.co.uk

3

13206

G.C. No. 41-019-07

G.C. No. 41-019-08

Ultracom 

18sxi

Ultracom 

30sxi

Summary of Contents for Ultracom sxi

Page 1: ...www glow worm co uk 1 www glow worm co uk T o b e l e f t w i t h t h e u s e r Instructions for Use High Efficiency Condensing Boilers Ultracom sxi...

Page 2: ...her on or off Open all doors and windows ventilate the area METAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to edges...

Page 3: ...www glow worm co uk 3 13206 G C No 41 019 07 G C No 41 019 08 Ultracom 18sxi Ultracom 30sxi...

Page 4: ...er Control Panel 9 Lighting the Boiler 10 Adjusting Temperature 11 Fault Finding 11 These instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety In...

Page 5: ...ation is made to the boiler unless approved in writing by Glow worm Any alteration not approved by Glow worm could invalidate the certification boiler warranty and may also infringe the current issue...

Page 6: ...t the boiler operates automatically Pluming from flue terminal Like all condensing boilers it will produce a plume of condensation from the flue terminal in cool weather This is due to the high effici...

Page 7: ...tivate if the boiler temperature does not reach 10 O C after 30 minutes or at any time if the temperature drops to 5 O C The burner will switch off when the temperature reaches 35 O C NOTE Any other e...

Page 8: ...solvent cleaner as you may damage the paintwork Servicing Maintenance and Spare Parts Frost Protection If the mains electricity and gas services are to be turned off for any long periods during severe...

Page 9: ...ith symbols the status of the boiler refer to diagram 2 Diagram 2 13473 Control Panel MODE PROG SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS System Pressure Max burner display Min burner display Temp...

Page 10: ...ols switch on the electrical supply to the boiler Lighting the Boiler 2 Select your required function refer to diagram 2 press Mode repeatedly to scroll through your options and select one of the foll...

Page 11: ...F and code number press the reset button on the control panel see diagram 2 If the display shows a flashing pressure of 0 4bar or less then the system will need to be pressurised If this or any fault...

Page 12: ...low worm co uk 12 Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT 0020020823 02...