1 G e n e r a l
150mm
445mm
445mm
150mm
MAXIMUM
SHELF
DEPTH
150mm
150mm
840mm
840mm
3917 S
FLAT AREA
FIRE FIXING FACE
Diagram 1.2
1.4 Fire Front Location
This fire front can only be fitted to a Glow-worm 45/2 or
56/2 back boiler unit which itself has been installed in
accordance with the Glow-worm Installation and
Servicing Instructions.
The back boiler air duct acts as a support for the fire
front.
The top of the fire front must be secured to the vertical
fire front fixing wall face. This wall face may be a
chimney breast or surround, see diagram 1.2.
The fire front flue spigot projects into the back boiler
flue collector assembly.
The gas supply is taken from the back boiler gas service
cock.
The back boiler must be correctly positioned in the
builder’s opening as the fire front is located by
connection to it.
1.5 Clearances
Restrictions must not be placed around the assembled
fire front, see diagram 1.2.
A shelf or surround of a maximum depth of 150mm may
be fitted, provided clearances are as shown in
diagram 1.2. However, for every additional 25mm extra
above the fire front the depth of the shelf may be
increased by 25mm.
Combustible furniture or materials must not be placed
closer than 1metre in front of the fire front.