Glow-worm ENERGY 12s -A Operating Instructions Manual Download Page 9

Product description 3

0020200965_02 ENERGY ..s Operating instructions

9

3

Button

4

Button

5

Fault clearance
key

3.6.1 Description of the display

1

2

3

1

Operating in-
formation

2

Active operating
mode, selecting
and confirming
the operating
mode

3

Filling pressure,
additional in-
formation

Symbol

Meaning

Burner operating correctly

Burner on

Heating installation filling
pressure

Permanently on: Filling
pressure in the permitted
range.

Flashing: Filling pres-
sure outside the permitted
range.

DHW mode

Permanently on: Hot wa-
ter activated

Flashing: Burner on in
draw-off mode

Eco hot water handling
mode

Hot water temperature
50 °C

Normal operating temper-
ature

Warm start for hot water
deactivated (combination
unit)

Symbol

Meaning

Heating mode

Permanently on: Heating
mode activated

Flashing: Burner on in
heating mode

Display flashing:

Switching on the product

Fault

Setting confirmed

/

Fault in the product

Appears instead of the
basic display.

OFF

Appears when switching
the product to standby
mode.

3.6.2 Description of button

functions

Button

Meaning

Selecting the operating mode

Confirm the operating mode

Confirm setting

Increase the display contrast

or

Setting the hot water temperat-
ure

Setting the heating flow tem-
perature

Increase or decrease the selec-
ted setting

Increase the display contrast

Activate the product: On/off
(standby)

Reset the product

Adjustable values flash on the display.
You must confirm any change to a value.
Only then is the new setting saved.
If you do not press any buttons for five
seconds, the displays switches back to
the basic display.
If you do not press any buttons for one
minute, the display contrast decreases.

Summary of Contents for ENERGY 12s -A

Page 1: ...The energy you need Operating instruc tions ENERGY s ENERGY 12s A H GB ENERGY 15s A H GB ENERGY 18s A H GB ENERGY 25s A H GB ENERGY 30s A H GB GB IE...

Page 2: ...Checking the heating system pressure 10 4 4 Filling the heating installation 11 4 5 Selecting the operating mode 11 4 6 Setting the hot water temperature 11 4 7 Setting the heating flow temperature 1...

Page 3: ...ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with...

Page 4: ...void rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains...

Page 5: ...ake any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the drain p...

Page 6: ...design instructions Do not fit the casing on the product yourself If you require cabinet type casing for the product consult an approved heating special ist company 1 3 11 Risk of material damage cau...

Page 7: ...stic heating and hot water systems in the UK and to en courage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hotwater Industry Co...

Page 8: ...densing technology Efficiency class of the boiler in accordance with EC Dir ective 92 42 EEC Type Xx3 x Permissible flue gas connec tions PMS Maximum water pressure in heating mode PMW Maximum water p...

Page 9: ...ning Heating mode Permanently on Heating mode activated Flashing Burner on in heating mode Display flashing Switching on the product Fault Setting confirmed Fault in the product Appears instead of the...

Page 10: ...water valve and see whether water is escap ing there 4 1 2 Switching on the product Switch on the product via the main switch installed on site 4 2 Basic display The filling pressure in the heating in...

Page 11: ...Fill with water until the required filling pressure is reached 4 Check the filling pressure in the display 5 Close the filling cock after filling 4 5 Selecting the operating mode Note The unit is alw...

Page 12: ...d the display will show OFF and go out The product is now in standby mode The product s frost protection func tion is activated The main power supply is not inter rupted The product continues to be su...

Page 13: ...cold water stop cock 7 2 Permanently decommissioning the product Have a competent person permanently decommission the product 8 Recycling and disposal The competent person who installed your product i...

Page 14: ...e building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is set too low or to the Heating off positio...

Page 15: ...e fault persists and you have pressed the fault clearance key once more a burner anti cycling time of 45 minutes is automatically activated The display shows S 54 If the fault persists consult a compe...

Page 16: ...639 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020200965_02 21 10 2016 These instructions or parts thereof are protected by copyright and may be reproduced...

Reviews: