background image

Product dimensions

Range

A

B

C

D

E

F

Height

Width

Depth

Flue Outlet 

position 1

Flue outlet 

position 2

Ø80/125 

Flue 

diameter

Easicom

Easicom 24 (mm)

740

418

338

130

1

125

Easicom 28 (mm)

740

418

338

130

1

125

A

D

C

E

F

B

Easicom

Specifications

Easicom specifications - Combi

Easicom

24

28

Size

Casing dimensions (h w d)(mm)

740/418/338

740/418/338

Weight (lift)

37kg

38kg

Performance

CH output (kW) Min/Max

7.7/18

8.8/23.3

DHW output (kW) Min/Max

8/24

9.3/28

DHW flow rate storage/combi (l/min. 35°C rise)

9.8

11.5

SEDBUK rating 2009

89.0

88.5

Nox class 5 (natural gas)

Yes

Yes

LPG Compatible

Yes

Yes

Construction

Main heat exchanger type

Coiled tube

Coiled tube

Heat exchanger material

Stainless steel

Stainless steel

Burner type

Pre-mixed

Pre-mixed

Fully modulating

Yes

Yes

DHW plate heat exchanger

Yes

Yes

Integrated hydrobloc

Yes

Yes

Installation

Suitable for sealed systems

Yes

Yes

Suitable for open-vent systems

No

No

Filling loop

No

No

Inbuilt automatic bypass

Yes

Yes

Inbuilt adjustable system bypass

No

No

Inbuilt condensate trap/siphon

Trap

Trap

Inbuilt boiler frost protection

2 stage

2 stage        

Zero compartment ventilation

Yes

Yes

Clearances

Top (mm) (from top of boiler)

150

150

Side (mm)

0

0

Bottom (mm)

200

200

Front (mm)

2

600

600

User Interface

User display

2 digit LCD

2 digit LCD

Diagnostics

Advanced

Advanced

User adjustable CH temp control

Yes

Yes

User adjustable DHW temp control

Yes

Yes

Eco setting on DHW

No

No

Pre-fitted analogue timer

Yes

Yes

Pipes

Pre-fixing jig

No

No

Optional spacing frame

No 

No

Water connections

2x22/2x15mm 

2x22/2x15mm

Flues

Max horizontal ØØ60/100

6m

6m

Max vertical Ø60/100

6m

6m

Max horizontal Ø80/125

10m

10m

Max vertical Ø80/125

10m

10m

Optional plume management kit

Ø60/100

Yes

Yes

Product clearances

Range

A

B

C

D

E

F

G

Top flue

Top

Side

Bottom

Flue#1

Flue#2

Front

Easicom

Easicom 24 (mm)

150

5

0

200

5

5

600 

2

Easicom 28 (mm)

150

5

0

200

5

5

600 

2

Notes:

1

  Flue is central to the boiler. 

2

  A removable compartment door can be placed at least

  5mm in front of the appliance.

D

C

C

A

B

G

E

F

Easicom

11

10

Summary of Contents for Easicom

Page 1: ...gham Road Belper Derbyshire DE56 1JT www glow worm co uk Head Office 01773 824 639 Literature 01773 596 105 After Sales Service 01773 828 100 Technical Advice 01773 828 300 Boilers 08447 361 143 Renew...

Page 2: ...zontal flueing options flueing accessories 12 Vertical flueing options flueing accessories 13 Expert support from start to finish 14 15 Disclaimer This Technical Guide is intended as a guide only and...

Page 3: ...y Easy to use Extra low voltage Simple discreet 2 wire connection Wiring polarity not important Climapro Programmable room thermostat Time and temperature Simple 2 channel controller for central heati...

Page 4: ...porate excellent insulation that achieves heat loss as low as 1 7kWh 24hrs and a high recovery heating coil that reheats the cylinder in as little as 20 minutes Key Features Hydracyl available in 150...

Page 5: ...white the Plume Deflector Kit can be installed quickly and simply onto a horizontal flue instead of the standard terminal end piece during or after installation Condensate Pump To solve problems assoc...

Page 6: ...lling loop No No Inbuilt automatic bypass Yes Yes Inbuilt adjustable system bypass No No Inbuilt condensate trap siphon Trap Trap Inbuilt boiler frost protection 2 stage 2 stage Zero compartment venti...

Page 7: ...ue length must not be exceeded Vertical flue options A H L I M B J K F G C D E F C D E G M F C D E C D E B B G M F C D E C D E A G M Vertical flue accessories Component Description Part Number 60 100...

Page 8: ...s and spares network Glow worm provide you with expert help and support whenever you need it Product warranty All Glow worm products are designed to exacting industry standards and are individually te...

Reviews: