Important Safety 
Precautions

Repairs to GLORIA house and gar-
den equipment should only be car-
ried out by GLORIA Service Sta-
tions. Order spare parts from your
authorised GLORIA dealer. If the
required parts are not in stock, he
will procure them for you as
quickly as possible.

These GLORIA high pressure spray
units are suitable to deliver all types
of spray agent (for Group 2 fluids in
accordance with Directive
97/23/EC) in hobby, handicraft and
industrial applications.

Only use normal commercial prod-
ucts, by themselves (pH value 
5-10). Mixtures of differing products
can cause unpredictable and dan-
gerous chemical reactions. The tank
is not to be filled with acidic materi-

als with pH value 

≤ 

5 or with sol-

vents or strongly corrosive agents.

Observe the instructions provided by
the manufacturer of the agent being
sprayed. Certain spraying agents re-
quire face masks, protective
glasses, protective gloves or other
safety measures.

Observe the guidelines for liquid jet
pumps ZH 1/406: The liquid jet pump
is to be inspected by a trained techni-
cian as required, and at least every 12
months, to ensure that continued safe
operation is possible. The instructions
of the manufacturer are to be fol-
lowed. The inspection can be delayed
until the next time that the unit is used
if it is to be put away for some time
(see Emptying and Servicing).

Ignitable explosive mixtures must
not be used. Exception: in an area
not at risk from explosion. In such a
case the Guideline for Protection
Against Explosion (EX-RL) and the
Ordinance on Inflammable Liquids
(VbF) must be observed, keep the
unit in a well-ventilated area, away
from sources of ignition, do not
smoke, keep it away from inflam-
mable materials. Do not pour the
residue down the drain. Avoid the
buildup of electrostatic charges
through earthing (see Startup). 
In the event of a fire, use fire class B

Summary of Contents for Profiline 405T

Page 1: ...9001 DE IT DK PL RU GR DE IT DK PL RU GR GB GB GB ES PT TR IT ES PT TR IT ES PT TR IT ES PT TR PL CS SK SL HU RO EL 405 T 405 TKS 505 T 410 T 410 TI 410 TRK 410 TKS 510 T 510 TRK Ger te f r Haus und...

Page 2: ...1 3 2 5 L Profiline 405 T 405 TKS 505 T 4 5 RZ qxd 12 01 2009 12 01 Uhr Seite 5...

Page 3: ...6 7 5 L Profiline 405 T 405 TKS 505 T 1 10 9 8 11 RZ qxd 12 01 2009 12 06 Uhr Seite 5...

Page 4: ...13 10 L Profiline 410 T 410 TI 410 TRK 410 TKS 510 T 510 TRK 1 16 15 17 14 12 17a RZ qxd 12 01 2009 12 23 Uhr Seite 5...

Page 5: ...19 10 L Profiline 410 T 410 TI 410 TRK 410 TKS 510 T 510 TRK 20 21 23 18 22 RZ qxd 12 01 2009 12 23 Uhr Seite 5...

Page 6: ...410 TRK 510 TRK 26 27 29 24 25 28 1 2 3 4 5 90 90 1 2 1 2 1 2 RZ qxd 12 01 2009 12 24 Uhr Seite 5...

Page 7: ...f valve x x x x x x x x x Backrest x x x x x x Safety features Safety valve with pressure relief valve manometer Nozzle standard Fan jet 80 x x x x x x x x x Max spray capacity 1l min 1l min 1l min 1l...

Page 8: ...5 or with sol vents or strongly corrosive agents l Observe the instructions provided by the manufacturer of the agent being sprayed Certain spraying agents re quire face masks protective glasses prote...

Page 9: ...inance Tech nicalInstructionAir TA Luft l Do not leave the filled tank in strong sunshine Do not exceed operating temperatures of 50 C l Store the unit in a place out of the reach of children l Do not...

Page 10: ...de and screw the spray tube onto the tank 10 litre units Fitting the carrying straps Fig Fitting the top carrying strap Fig Fitting the bottom carrying strap Fig Adjusting the carrying straps l The ca...

Page 11: ...connection must not be re moved to depressurize the tank Fill tank Caution Operate the pressure relief valve red button until the unit is no longer under pressure l Remove the pump by turning it to th...

Page 12: ...the pump and screw into posi tion l Operate the pump until an operating pressure of 6 bar red line on manometer in the tank has been reached Spraying l To start the spraying process push the operating...

Page 13: ...ion the handle on the pin of the case part Attention The handle must point backwards as illustrated 2 Now push the handle down to the stop on the pin the detents must engage in both holes Position and...

Page 14: ...pray unit and to ensure that spray compound residues are neutralised we recommend the use of GLORIA Special Activated Charcoal Art No 263 0000 l Important note Undue strain caused by the mode of opera...

Page 15: ...r when the unit is being transported or is not in use 1 3 5 7 2 4 6 8 9 10 11 11a 12 13 15 15a 16a 17a 17 19 14 16 18 20 21 22 23 24 25 27 29 31 26 28 30 32 33 34 35 36 3 5 7 4 6 8 9 10 11 11a 12 15 1...

Page 16: ...ly with the directive on pressurized equipment 97 23 EG and the recognized rules of technology The procedure for the statement of conformity for the module and for the tank os based on module A1 Appen...

Reviews: