Glomar Dr.Peters EPG-5-ULTRA Instruction Manual Download Page 10

Bedienungsanleitung / Instruction manual  EPG-5-ULTRA

10

Glomar AG

  

l

  

Seestrasse 11

  

l

  

CH-9326 Horn

  

l

  

T +41 71 841 70 70

  

l

  

www.glomar.ch

1

Instruction Manual Crimping tool

GB

authorised

copy

Index

1.   Introduction

2.   Warranty

3.   Description of the electric-hydraulic 

crimping unit

3.1   Description of the components

3.2   Brief description of the important features 

of the unit

3.3   Description of the tool indication

4.   Remarks in respect of the determined use

4.1   Operation of the units

4.2   Explanation of the application range

4.3   Mounting instructions

4.4   Service and Maintenance instructions 

5. Troubleshooting

6. 

Technical data 

7. 

Putting out of operation/waste disposal

Symbols

Safety warnings
Please do not disregard these instructions in or-

der to avoid human injuries and  environmental 

damages.
Operational warnings
Please do not disregard them to avoid dama-

ging the pump unit.

1. Introduction

Before starting to use the tool please read 

the instruction manual carefully.

Use this tool exclusively for its determined use.
Mounting and assembly of connecting material with the 

help of this tool must only be performed by specially trai-

ned personnel. The minimum age is 16 years.
This instruction manual has to be carried along during the 

entire life span of that tool.
The operator has
•  to guarantee the availability of the instruction manual 

for the user and

•  to make sure, that the user has read and understood 

the instruction manual.

2.   Warranty

If the tool is operated according to its intended 

use and the regular maintenance services are 

observed our warranty is 24 months from the 

time of delivery. Worn-out parts resulting from its 

intended use are excluded. We reserve the right 

to rework the tool in case of a justi

 ed warranty 

claim.

3.  Description of the electric-hydrau-

lic crimping tool

3.1  Description of the components

The electric-hydraulic crimping unit is a hand guided tool 

and consists of the following components: 
Table 2 (see Picture 1)

Pos. Description

Function

1

LED (red)

indicator for tool functions 

and battery charge control

2

Battery 

cartridge

rechargeable 3Ah Li-Ion 

battery (RAL2/BL1830)

Optional:

mains adapter NG2230

3

Trigger

switch to start crimping 

procedure

4

Retract button button to open the dies 

in case of emergency

5

LED (white)

to illuminate the working area

6

Locking pin

Pin neccessary to close the 

crimping head

7

Indenter

3 moving and 1 stationary 

indenter

8

Ring

device to secure the crimping 

tool

9

Housing

ergonomically formed plastic 

housing in a 2-Component 

design for perfect handling

3.2  Brief description of the important 

 

features of the unit

The hydraulic unit incorporates an automatic retrac-

tion which returns the piston into its starting position 

when the maximum operating pressure is reached.

A manual retraction allows the user to return the pis-

ton into the starting position.

An automatic retraction stops the retraction of the 

piston depending on the connector size which sa-

ves time and energy.
The unit is equipped with a special brake which 

stops the forward motion of the piston/dies when 

the trigger is released.
The unit is equipped with a double piston pump 

which is characterised by a rapid approach of the 

dies towards the connector and a slow crimping 

motion.
The crimping head can be smoothly turned by 350° 

around the longitudinal axis in order to gain better 

access to tight corners and other dif

 cult  working 

areas.
The tool is equipped with a microprocessor which 

indicates service intervals and low battery charges 

and performs internal checks sending out acousti-

cal and optical warning signals in case of a detected 

fault.

All tool functions can be controlled by 

one

 trigger. 

This results in an easy handling and a better grip 

compared to a two button operation.

HE.17007 © 10/2015

EPG-5-Ultra

®

 

Dr. Peters

®

Summary of Contents for Dr.Peters EPG-5-ULTRA

Page 1: ...Bedienungsanleitung Instruction manual Glomar AG l Seestrasse 11 l CH 9326 Horn l T 41 71 841 70 70 l www glomar ch EPG 5 ULTRA ...

Page 2: ...A 2 Glomar AG l Seestrasse 11 l CH 9326 Horn l T 41 71 841 70 70 l www glomar ch I Bedienungsanleitung Instruction Manual 6 7 HE 17007 10 2015 EPG 5 Ultra Dr Peters 6 7 5 1 4 3 2 BL1830 RAL2 optional NG2230 8 9 Bild pic g 1 siehe see Tab 3 2K HE 15333 ...

Page 3: ... June T Dec 1 1 2 3 4 Bild pic g 2 Bild pic g 3 Bild pic g 4 BL1830 22 min RAL2 10 40 C CLICK Bild pic g 5 Bild pic g 6 Bild pic g 7 Bild pic g 8 Bild pic g 9 Bild pic g 10 Li ion Bild pic g 11 884676B996 884598C990 Bild pic g 12 Auf dem Knapp 46 D 42855 Remscheid HE 17007 10 2015 EPG 5 Ultra Dr Peters Dr Peters HE 13543 M A D E I N G E R M A N Y Dr Peters Auf dem Knapp 57 D 42855 Remscheid Dr Pet...

Page 4: ...Seestrasse 11 l CH 9326 Horn l T 41 71 841 70 70 l www glomar ch III Bedienungsanleitung Instruction Manual Bild pic g 13 1 2 t PRESS tr tr tr tr auto set reset Bild pic g 14 Bild pic g 15 O I L 350 HE 17007 10 2015 EPG 5 Ultra Dr Peters 1 2 PRESS PRESS on off O 350 ...

Page 5: ... AG l Seestrasse 11 l CH 9326 Horn l T 41 71 841 70 70 l www glomar ch IV Bedienungsanleitung Instruction Manual Bild pic g 16 Bild pic g 18 Bild pic g 17 Bild pic g 19 PRESS Bild pic g 20 OIL 1 2 3 HE 17007 10 2015 EPG 5 Ultra Dr Peters 2 3 PRESS S S S S S S S ...

Page 6: ...ération de travail na bedrijfscyclus Después del proceso de trabajo после цикла опрессовки Çal şma işleminden sonra Efter arbejdsgang Fehler der notwendige Pressdruck wurde nicht erreicht Es handelt sich um eine manuelle Unterbrechung der Pressung bei stehendem Motor Error the required pressure has not been reached The opera tor has interrupted the pressing cycle manually while the motor was not r...

Page 7: ...cht vor das Produkt nachzuarbei ten 3 Beschreibung des elektro hydraulischen Presswerkzeugs 3 1 Beschreibung der Komponenten Das elektro hydraulische Presswerkzeug ist ein handge führtes Werkzeug und besteht aus folg Komponenten Tab 2 siehe Bild 1 Pos Bezeichnung Funktion 1 LED rot Kontrollinstrument zum Feststel len des Ladezustandes eines Werkzeugfehlers und zur Wartungsanzeige 2 Akku wiederau a...

Page 8: ...m Ende einer Pressung erkannt werden 4 Hinweise zum bestimmungs gemäßen Gebrauch Vor Arbeitsbeginn sind alle aktiven d h stromführenden Teile im Arbeitsumfeld des Monteurs freizuschalten Ist dieses nicht möglich sind entsprechende Schutzvorkeh rungen für das Arbeiten in der Nähe von unter Spannung stehenden Teilen zu treffen Halten Sie Ihren Arbeitsbereich sauber und aufgeräumt Verwenden Sie diese...

Page 9: ...dem Einsatz des elektrischen Gerätes von quali ziertem Fachpersonal oder durch unser Klauke Service Center ASC reparieren 5 Verhalten bei Störungen am Werk zeug a Regelmässiges Blinken Leuchten der roten Leucht diode Bild 1 1 oder Ertönen eines akustischen Warnsignals siehe Tabelle 1 Sollte sich die Störung nicht ab stellen lassen ist das Werkzeug an das nächst gelegene Service Center ASC zu schic...

Page 10: ...g tool 3 1 Description of the components The electric hydraulic crimping unit is a hand guided tool and consists of the following components Table 2 see Picture 1 Pos Description Function 1 LED red indicator for tool functions and battery charge control 2 Battery cartridge rechargeable 3Ah Li Ion battery RAL2 BL1830 Optional mains adapter NG2230 3 Trigger switch to start crimping procedure 4 Retra...

Page 11: ...ar live parts must be provided Keep your working area clean and tidy Do not use this tool when you are tired on drugs had alcohol or if you are medicated 4 1 Operation of the unit Cycle see pictures in front Attention Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Attention Keep proper footing and balance at all times Attention Use ...

Page 12: ...facturer Do not open it and damage the seal of the tool c The red LED ashes 3X and simultaneously 3 accu stic warning signals occure see table 1 Serious fault If this fault occures repeatedly return the unit to an Autorized Service Center ASC Do not open it and damage the seal of the tool In case of a one time occurence the connector has to be crimped a second time HE 17007 10 2015 EPG 5 Ultra Dr ...

Page 13: ...taavana todistamme täten että tämä tuote on seuraavien standardien ja standar doimisasiakirjojen vaatimusten mukainen EN 60745 1 EN ISO 12100 EN ISO 13857 EN 349 EN 60204 1 EN 28662 1 EN 61000 6 3 EN 61000 6 2 EN 60529 EN 1037 ja vastaa säädoksiä 2006 42 EG 2014 30 EU 2011 65 EU N CE 15 Konformitetserklæring Vi erklærer på eget ansvarlighet at dette produkt er i overensstemmelse med følgende stand...

Reviews: