Globus HT-922 Instruction Manual Download Page 27

27

elements (Es. Table or chairs).

Use

-

Insert the power adapter supplied with the unit.

- Connect  the  cable  supplied  to  the  polar  socket (see
picture pag.4) and

insert the  electrodes  in  the  specific  plug.  Apply  the

electrodes on the dermis.
- Put some gel on the ultrasonic probe.
- Push the “Up” button to turn on the unit.
- Keep pushing the “Set” button for 2 sec.
- Push again twice the “Set” button.
- The notice “Es” flashes.
- With the “Up” button select one of the Combo programs
(P7 or P8 or P9)
- Push “Set” to confirm.
- Push “Up” or “Down” to set up the desired power.
- Choose the intensity level between the 9 available ones.
- To  switch off  the  device,  lead  the  intensity level  to  the  0
level and
push “Down”.
- To change the default settings push the “Set” button once,
the “Timer” will flash  on the display.
- Push the “Up” or “Down” button to set up the desired time
(from 0 to 30 min.)
- When the time setting is complete, push  “Set” once and
the notice “ES” will flash on the display.
- Push the “Up” and “Down” button to select the programs
“P4-P5-P6”. Confirm the program with the “Set” button.
- Push the “Up” or “Down” button to select the power.
- at  the  end  of  the  program  the  device  will  automatically
switch off.
- to return to the Ultrasound mode, keep pushing the “Set”
button for 2 seconds

Summary of Contents for HT-922

Page 1: ...1 REV 1 M Me ed di is so ou un nd d 9 92 22 2 I In ns st tr ru uc ct ti io on n M Ma an nu ua al l...

Page 2: ...2...

Page 3: ...REQUIRED The device has been produced by Home Care tecnology CO LTD 116 Lane 523 SEC 3 JONGJHENG RD RENDE DIST TAIWAN CITY TAIWAN hometech hometech com tw Imported and distributed by Domino s r l via...

Page 4: ...NDS 16 THERAPEUTIC INDICATIONS 18 Theraupetic effects 18 Ultrasounds application for beauty 20 Effects on aesthetic treatments 20 The adipose tissue 21 MODE OF USE SONOPHORESIS PROGRAMS 22 MODE OF USE...

Page 5: ...10 min Temperature max 45 set up standard 40 Intermittent switch 10 sec switched off MENS OUTPUT POWER o 1 VDC 9 intensity level TIMER from 1 to 30 min Set up standard time 10 min ADAPTER AC TYPE 48 2...

Page 6: ...oximity less than 1 meter of electrical appliances that emit small waves or microwaves in so far as the emission could result instable in the work frequency IEC601 2 10 Conditions of conservation and...

Page 7: ...arefully read this operating manual Examine with care the apparatus and its parts to individuate eventual external damages if the control unit is on but no indicators light up on the screen switch off...

Page 8: ...y out an ultrasound treatment on another person it is necessary to use also the adhesive electrodes placing them on the person to treat in this way the circuit will be closed The device can be regulat...

Page 9: ...hinner gasoline kerosene cleaning powder or chemicals for cleaning the machine and the cables it is sufficient a soft lightly humid duster After a long period of non use it is advisable to check the c...

Page 10: ...products and not original spare parts will induce the loss of warranty Use it for maximum 30 minutes then keep it switched off for 30 minutes to dissolve the electronic components Keep the device in p...

Page 11: ...pregnancy as diagnostic instrument is different from that used for therapeutic aims Patients with pacemaker should not be treated with ultrasound on thorax or column because the generator can have ba...

Page 12: ...ollowing therapeutic modality described in this manual The user must keep the device out of reach of children or people with mental competence Only producer accessories must be used with this device D...

Page 13: ...me the Timer will flash lights on the display push the button Up and Down to set up the desired time from 0 to 30 min When you have finished the setting up push Set once the unit places itself on stan...

Page 14: ...re that ther are not any traces of cleanser or other products When the program starts it is recommended to make first penetrate the anti cellulite cream and later apply the Globus gel Start the progra...

Page 15: ...e machine and to the medical and paramedical personnel What are Ultrasound Ultrasound is defined as an acoustic vibration with frequencies above the limit of audible sounds superior of 20 000 Hz Ultra...

Page 16: ...ge of ultrasounds through the soft tissues creates an elevation of the temperature for absorption due to the viscosity absorption due to the thermic conductivity and chemical absorption The ultrasound...

Page 17: ...duced in the tissues then greater its efficacy in the lipolysis Adipose cells in particular are more easily exposed to the cavitational effect than the more resistant structures The dynamics of the pr...

Page 18: ...diment It is useful to improve the efficancy of the kinesiotherapy sessions It can be used as analgesic in the arthritic and periarthritic symptoms to facilitate the hematoma reabsorption to stimulate...

Page 19: ...e trophism facilitate the repair of the damaged tissues and accelerate the resolution of the inflammatory processes The ultrasounds are used for the treatment of tendon capsular periosteal structures...

Page 20: ...substances like essential oils fat soluble vitamins cosmetic products emulsions water soluble agents through the epidermis They stretch the tissues the ultrasound thanks to the thermic and mechanical...

Page 21: ...d their slump Massage program designed to delate the muscular nervous tensions Specific to relaxe the tens musculature Scars program designed for the skin trophic status and to distance the skin physi...

Page 22: ...of tissue known as brown is present in little quantities in newborn With the growth a great part of it becomes white adipose tissue for this reason there are in adults only a very little quantity of b...

Page 23: ...process in a not meticulous way this effect can causes irritation and burns on skin The skin must not be injured do not shave your skin before the treatment to avoid micro cuts caused by the razor Per...

Page 24: ...or P2 or P3 Confirm the program with the Set button Push the Up or Down button to select the power At the end of the program the device will automatically switch off To return to the Ultrasounds mode...

Page 25: ...lied with the unit Connect the cable supplied to the polar socket see picture pag 4 and insert the electrodes in the specific plug Apply the electrodes on the dermis Put some gel on the ultrasonic pro...

Page 26: ...gether with the metal part of the treatment head These applications are for medical aim therefore they have to be carried out only with medical personnel approval The COMBO technique permits to exploi...

Page 27: ...set up the desired power Choose the intensity level between the 9 available ones To switch off the device lead the intensity level to the 0 level and push Down To change the default settings push the...

Page 28: ...0 min Level 5 painful zone Scars 18 min Level 4 interested zone Carpal tunnel 20 min Level 6 pic 7 Tennis arm 20 min Level 7 pic 3 Periarthritis 20 min Level 7 pic 11 Sprain 20 min Level 8 pic 14 Heel...

Page 29: ...Stretch marks 30 min level 8 interested zone Absorption Active principles 25 min level 9 interested zone Skin Duration Intensity and ref picture Cellulite 30 min level 9 interested zone Fat 30 min lev...

Page 30: ...ow 10 minutes Ideal for the carriage of the active principle in small articulations P2 Medium 10 minutes Ideal for the carriage of the active principle in big medium articulations P3 High 10 minutes I...

Page 31: ...ne Neuralgia P4 P5 Level from 7 to 9 painful zone Knee pain P4 P6 Level from 7 to 9 Pic 18 Trazpezius pain P4 P6 level from 7 to 9 Pic 19 Thigh pain P4 P6 level from 7 to 9 Pic 20 Shoulder pain P4 P6...

Page 32: ...P9 Level 8 Pic 18 Trapezius pain P7 P9 Level 8 Pic 19 Thigh pain P7 P9 Level 8 Pic 20 Shoulder pain P7 P9 Level 8 Pic 21 Elbow pain P7 P9 Level 8 Pic 22 Hip pain P7 P9 Level 8 Pic 23 Sciatica P8 Level...

Page 33: ...trol the power supply contact the dealer Intermitting vibration too much high temperature circuitry anomaly mixed wave decrease the intensity level interject the gel or some cream on the machine s hea...

Page 34: ...ation of the treated areas Is it always necessary to use the Globus Gel on skin and treatment head Yes and the quantity must be sufficient for all the involved area otherwise the ultrasounds are not t...

Page 35: ...nd a healthy life style If the treatment cable should have fissures or the cable should be damaged can I use them Absolutely not How many treatments Do I have to carry out It is recommended on the sam...

Page 36: ...repair will not affect the original expiry date of the guarantee and will not lead to the renewal or extension thereof 4 In case when the repair work we find no defect in the product itself will stil...

Page 37: ...on com always accessing Club My Globus Area Globus product support may be required to the dealer where you purchased the product or visiting Globus website in the Club my Globus Images features and da...

Page 38: ...38 AREAS TO TREAT...

Page 39: ...39 SOME AREAS TO TREAT SONOFORESI MENS COMBO...

Page 40: ...40...

Reviews: