background image

 

 

 

Getting to Know the Labdisc 

Globimate version 

 

 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 

 

 

www.globisens.com

 

 

Summary of Contents for Labdisc

Page 1: ...Getting to Know the Labdisc Globimate version www globisens com...

Page 2: ...4 Set up 4 Run Stop 4 Download 4 Mathematical Functions 4 Activities 4 Working On A Smaller Screen Error Bookmark not defined Other Software Features 5 Zoom 5 Marker 5 Annotate 5 Display Options 5 Use...

Page 3: ...Error Bookmark not defined Turbidity Sensor 7 UV Sensor 8 Voltage 8 Available External Sensors 8 Dymo Wireless Force Accelerometer Error Bookmark not defined Voltage Sensor Error Bookmark not defined...

Page 4: ...to confirm your choice Options include manual 1 second 10 second 100 second 1000 second and 25000 second The rate of collection by some sensors is limited and so you may not see all of the options for...

Page 5: ...sensors are available If you are using a Globisens brand external sensor attached to the Universal Adapter port it will show up in the set up menu after you have attached it If you are using a sensor...

Page 6: ...be in different places on different tablets It may be a column of three small boxes to the far right at the top of the screen or it may be a small menu at the bottom of the screen near the back arrow...

Page 7: ...rates Globilab will limit the collection rate to that of the slowest sensor Run Stop this allows you to begin or stop the collection of data Like the set up button this button will only work if the L...

Page 8: ...and drag the bubble anywhere within 360 degrees of its insertion point You can also lengthen shorten the leader to the text by dragging the text bubble closer to further from the insertion point To mo...

Page 9: ...Press and hold the colorimeter button on the Labdisc until you hear a long beep When finished the calibration remove the cuvette from the colorimeter To take a data reading fill the cuvette full with...

Page 10: ...g turn The pH meter will measure the H ion activity in a solution The pH sensor is factory calibrated and under normal conditions does not require any calibration If you need to calibrate this sensor...

Page 11: ...ation You will see the blue light flash 3x Then right click on the Bluetooth icon in the lower right corner of the Globilab window and click on Find More Labdiscs and sensors When the add a device win...

Page 12: ...ndividual wave forms of each heartbeat but will not show a graph line indicating the overall heart rate The pulse waveform will be measured in Volts V Respiration Prior to using the Respiration sensor...