The G.Saver II Retractable Fall Arrest Lifeline & Retrieval System
-
5
-
4.1
Anchorage Requirements
Anchorages to EN 795 may be
used.
Anchor points must have a
minimum static strength of
1225kg (12kN) per attached
G.Saver II.
4.2
Connectors
Connectors used with the G.Saver II should be to EN 362
or equivalent.
Metal connectors must have a minimum strength of
1530kg (15kN), in the direction of loading.
Webbing products or non-metallic connectors must have
a minimum strength of 2240kg (22kN). These must not
be used in contact with sharp edges or rough abrasive
surfaces that may cause damage.
Lanyards must not be used to extend the length of the
wire rope. Where deemed suitable by the harness
manufacturer, a short strap (0.5m maximum length) may
be fitted, to extend the attachment point of the full body
harness allowing easier connection of the safety hook.
4.3
Attaching to the User
The User must wear a Full Body Harness that meets the
requirements of EN361. Connect the G.Saver II’s Safety
Hook Karabiner directly to the fall arrest attachment point of
the Harness. Ensure that the gate is closed and locked.