SERIES GL-QR/INCH/ECLH

EXTENDED COVERAGE, QUICK RESPONSE, LIGHT HAZARD

CONCEALED PENDENT SPRINKLERS

K-FACTOR: 5.6

4077 Airpark Dr. Standish, MI  48658 • 989-846-4583 • 

www.globesprinkler.com

Technical Support 

 989-414-2600

 

 

[email protected]

Note

:

 

Users should refer to Globe’s web site (www.globesprinkler.com) 
to assure that the most recent technical literature is being utilized.

GENERAL DESCRIPTION

The Globe Series GL-QR/INCH/ECLH sprinkler is a Listed 

Quick Response concealed sprinkler which utilizes a 3mm 

frangible glass bulb as the thermosensitive operating ele-

ment. It is Listed and Approved as an Extended Coverage 

sprinkler for Light Hazard Occupancies for a maximum cov-

erage area of 400 sq. ft. and is to be installed in accordance 

with the guidelines of the appropriate Installation Standard 

being mandated by the AHJ (i.e. NFPA 13). While providing 

the optimal aesthetic appeal with the low profile flat cover 

plate, the GL-QR/INCH/ECLH additionally provides the larg-

est vertical adjustment in the industry of a nominal 1”. This 

nominal 1” adjustment allows for previously unrecognized 

installation flexibility resulting in a clean and tight final “fit” to 

the ceiling. The sprinkler is available in three temperatures 

and the cover plate is available in two temperatures. The 

nominal K-Factor is 5.6 (80,6) and the threads are 1/2” npt.

TECHNICAL DATA

SIN

• 

GL5603

Approvals

• 

cULus - Light Hazard

Maximum Working Pressure

• 

175 psi (12 bar)

Minimum Operating Pressure

• 

See TABLE A

Minimum Spacing

• 

8 ft. (2.4 m)

Temperature Rating

• 

See TABLE A

Materials of Construction

• 

Frame - bronze 

 Deflector - brass 

 Screw - brass 

  Bulb seat - copper 

• 

Spring - nickel alloy 

 Seal - teflon

• 

Bulb - glass with alcohol based solution, 3mm

• 

Cover Plate - brass

• 

Upper Escutcheon Assembly - carbon steel 

SERIES GL-QR/INCH/ECLH EXTENDED COVERAGE, QUICK RESPONSE, 

LIGHT HAZARD CONCEALED PENDENT SPRINKLERS  K-FACTOR: 5.6

SERIES GL-QR/ECLH/INCH/ECLH EXTENDED COVERAGE, QUICK RE-

SPONSE, LIGHT HAZARD CONCEALED PENDENT SPRINKLERS  K-FAC-

TOR: 5.6

GFS-210

GFS-210

FINISHES AND ACCESSORIES

Sprinkler Finish

   

• 

Factory Bronze

Cover Plates

   

• 

Chrome 

 White Painted 

 Black Painted 

• 

Custom

Caution:

 

Factory painted cover plates must not be repainted. Non-factory 
applied paint may adversely delay or prevent sprinkler operation 

in the event of a fire.

Wrench

   •

  1/2” NPT 1” Adjustable Concealed 

 

P/N 332765

OPERATION

The  soldered  cover  plate  drops  off  the  retainer  assembly 

when exposed to heat, as from a fire, that has reached the 

plate’s Listed temperature rating exposing the sprinkler 

above. Upon the releasing of the cover plate, the deflector, 

which is connected to two guide pins, drops down below 

the ceiling into its intended position. As heat encompasses 

the glass bulb operating element of the sprinkler, the fluid 

in the bulb expands, compressing the air bubble within the 

bulb. When the air bubble can no longer compress, the fluid 

expansion causes breakage of the glass bulb, resulting in 

release of the water seat assembly, and discharge of water 

from the sprinkler.