Troubleshooting

ISSUE

CAUSE

SOLUTION

Charbroiler not lighting

Main gas line is closed

Open valve

Pilot light is not lit

Ignite pilot light

Cause unknown

Call for service

Flame is too high or too low

Adjustment knob is turned up or 

down

Adjust flame with control knob

Pilot light not staying lit

Flame is too low

Adjust pilot light flame height

Pilot tube clogged

Replace pilot tube. Call for service

Strong smell of gas in cooking area

Main gas line leak

Turn off main gas valve. 

DO NOT LIGHT FLAME, ignite 

anything, or turn/switch on anything 

electrical

Call fire department if needed and 

call for service

Cooking surface is heating up slowly Carbon build up

Ensure that the burners are kept 

clean and free from carbon build up/

debris

Gas type of unit needs to be 

converted

Unit ships from the factory Natural 

gas. Conversion from Natural Gas to 

L.P. is possible for this unit

Contact an authorized servicer or 

Globe. Do not attempt conversion on 

your own

If problems persist and the assigned solution does not remedy the issue, please call Globe’s Service Department at: 

at 866-260-0522.

Summary of Contents for GCB15G-CR

Page 1: ...instructions which must be strictly followed when using this equipment IMPORTANT SAFETY NOTICE Instruction Manual for the Globe Gas Countertop Charbroiler Models GCB15G GCB24G GCB36G GCB48G Char Stai...

Page 2: ...937 299 4147 E MAIL info globefoodequip com WEBSITE www globefoodequip com Globe Food Equipment Company 2014 03042014 Ver 1 Rev 3_2014 Index WARRANTY REGISTRATION SCAN THE QR CODE WITH YOUR MOBILE DEV...

Page 3: ...nnel come in contact with this equipment Please remember that Globe cannot anticipate every circumstance or environment in which this equipment will be operated It is the responsibility of the owner a...

Page 4: ...B149 2 as applicable and in accordance with local codes The appliance and its individual shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure...

Page 5: ...upplied gas pressure regulator is factory set at 6 Natural gas W C or 10 for L P 7 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Non combustible clearances 6 sides 152 mm...

Page 6: ...t when not in use when servicing or adjusting any parts or attachments and before cleaning Never leave the charbroiler on overnight Do not operate any equipment with a damaged or leaking gas line igni...

Page 7: ...ll as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned to ON The holes located in the front panel are pilot valve adjustments Use a screwdriver to turn...

Page 8: ...ing and dust from storage and shipping are burned off An hour at maximum for all burners is usually sufficient Radiant Charbroiler 1 Place the angled radiants in their position as shown in 8 1 2 Make...

Page 9: ...d a non abrasive cleaner to clean the stainless steel body of the charbroiler Wipe the polished areas with a soft cloth Daily Controls Unit should be turned off when not in use It is recommended that...

Page 10: ...ease debris and crumbs CAUTION If the catch tray is permitted to fill too high grease debris is likely to accumulate under the unit The catch tray drawer is removed by pulling forward USE CAUTION WHEN...

Page 11: ...ain gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is heating up slo...

Page 12: ...ESS OR PROFITS OR OTHER ECONOMIC LOSSES OR STATUTORY OR EXEMPLARY DAMAGES WHETHER IN NEGLIGENCE WARRANTY STRICT LIABILITY OR OTHERWISE This warranty is given only to the first purchaser from a retail...

Reviews: