background image

MADIC ITALIA 

 

 

 

 
 

                        

 

 

 

 

 

 

 

 

                           Mod.N:Q060R06

 

9

/

26

 

 

4.5

 

LASER SAFETY CONSIDERATION 

BV1000GTV contains a laser emitter and corresponding drive circuitry. The laser output is designed to 
remain within Class 1 laser safety limits under all reasonably foreseeable conditions including single faults 
in compliance with IEC 60825-1:2014 (third edition).  
 
The laser output will remain within Class 1 limits as long as the MADIC ITALIA recommended device settings 
(API settings) are used and the operating conditions specified are respected.  
The laser output power must not be increased by any means and no optics should be used with the 
intention of focusing the laser beam. 
 
The laser doesn’t require any control, adjustment or maintenance. 
 

Caution

: Use of controls or adjustments or performance of procedures other than those specified  

herein may result in hazardous radiation exposure. 
 

 

FIGURE 1 – LASER CLASS LABEL 

 

Laser characteristics: 

This device emits pulsed laser radiation with a period of 16.7 nanoseconds and 5 nanoseconds on time,  
resulting in a duty cycle of 30%. The wavelength is 945 nm. 
 

Compliance statement for Laser Notice 56: 

Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3., as described in 
Laser Notice No. 56, dated May 8, 2019. 
 

Manufacturing site: 

The indication Mxxx on the product label indicates the manufacturing site: 
M001 = MADIC ITALIA s.p.a. Via Volta 39 Cardano al campo 21010 Italy 
 

Manufacturing date: 

The manufacturing date is located on product label in the following format: 

MNFG: mm-yyyy 

m=month 

y=year 

Summary of Contents for MADIC BV1000GTV

Page 1: ...Mod N Q060R06 User Manual Revision R01 07 P N MAEU025 BV1000GTV ALL IN ONE UNATTENDED PAYMENT SYSTEM...

Page 2: ...ECIFICATIONS BV1000GTV 14 10 2 BV1000GTV SPECIFICATIONS 15 10 3 BV1000GTV FRONT VIEW 16 10 4 BV1000GTV REAR VIEW 17 10 4 1 CONNECTORS PINOUT 19 11 CABLES 20 11 1 POWER CABLE 20 11 2 S1 SERIAL CABLE 20...

Page 3: ...any screws to enter into area for non operators Not allow liquid to spill into the internal cabinet side Not allow anything to rest on the power cord or telecomm cords and ensure a properly routing of...

Page 4: ...the essential requirements of article 6 of Directive 2014 30 EU ETSI EN 300 330 1 Electromagnetic compatibility and Radio Spectrum Matters ERM Short Range Devices SRD Radio equipment in the frequency...

Page 5: ...on the restriction of certain hazardous substances in electrical and electronic equipment also known as RoHS Recast or RoHS2 and its amendment 2015 863 EU Specifically BV1000GTV do not contain the su...

Page 6: ...s Test Cab Damp heat steady state CEI EN 60068 2 6 Environmental Testing Part 2 6 Tests Test Fc Vibration sinusoidal Salt Mist test CEI EN 60068 2 11 Environmental Testing Part 2 11 Tests Test Ka Salt...

Page 7: ...ation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communications Howev...

Page 8: ...comply with Innovation Science and Economic Development Canada s Iicence exempt RSS s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must a...

Page 9: ...require any control adjustment or maintenance Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure FIGURE 1...

Page 10: ...fects 4 The device has been modified to be used in a country different from the countries for which has been designed or where applicable homologated or has been damaged by those modifications 5 The w...

Page 11: ...ding machine The shields may be solely for shielding purposes or may be part of the general kiosk vending machine design o Position the device so that it is angled in such a way to make PIN spying dif...

Page 12: ...MADIC ITALIA Mod N Q060R06 12 26 7 VIEW AND ORDER CODES FIGURE 3 Product Overview BV1000GTV PRODUCT CODE ORDER CODE DESCRIPTION 1ASA222 H01 FP BV1000GTV ORDEABLE ACCESSORIES ORDER CODE DESCRIPTION...

Page 13: ...nding NAMA requirements BV1000GTV has three payment acceptance technologies Contactless for EMV cards MIFARE cards or NFC mobile phones Contact for EMV cards or Loyalty programs cards Magstripe up to...

Page 14: ...14443B SAM Reader 2 SAM module connectors Communication 3 RS 232 serial ports 1 USB 2 0 OTG 1 USB Host 1 Ethernet 10 100MB Power supply DC from 9V to 42V 1500mA Battery Back up Primary Lithium Size Ma...

Page 15: ...ssor if previously set in shutdown AUDIO The device has a speaker for audio connected to a class D amplifier PROXIMITY DETECTION The proximity sensor is used to detect the proximity of a target in fro...

Page 16: ...MADIC ITALIA Mod N Q060R06 16 26 10 3 BV1000GTV FRONT VIEW FIGURE 4 Front View BV1000GTV...

Page 17: ...18 PIN1 VIN 9 42 Vdc PIN2 GND PIN3 GND PIN4 MAN Input active low S1 Serial Port Molex Micro Fit 3 0 single row P N 43650 0524 PIN1 GND PIN2 TX output RS232 PIN3 RX input RS232 PIN4 RTS input RS232 PIN...

Page 18: ...logic level 3 3V PIN3 GPI1 Input logic level 3 3V PIN4 NC PIN5 SCL I2C Clock Output PIN6 5V 100mA PIN7 GPO2 Output logic level 3 3V PIN8 GPI2 Input logic level 3 3V PIN9 NC PIN10 SDA I2C Data Bidirect...

Page 19: ...onnector Inside the Module SAM1 Connector Top Insertion on top SAM2 Connector Bottom Insertion on bottom 10 4 1 CONNECTORS PINOUT Molex Micro Fit 3 0 double row P N 43045 0418 Molex Micro Fit 3 0 doub...

Page 20: ...WR connection Connector Molex Micro Fit 3 0 4P double row PIN1 VIN PIN2 GND PIN3 NC PIN4 NC 11 2 S1 SERIAL CABLE Cable for S1 connection with a DB9 interface Connector Molex Micro Fit 3 0 4P Single ro...

Page 21: ...IC ITALIA Mod N Q060R06 21 26 11 3 CABLE FOR S2 S3 CONNECTION WITH A DB9 INTERFACE Connector Molex Micro Fit 3 0 4P Single row Connector DB9 Female PIN1 GND PIN5 PIN2 LEFT OPEN PIN3 TX PIN2 PIN4 RX PI...

Page 22: ...MADIC ITALIA Mod N Q060R06 22 26 12 MECHANICAL DIMENSIONS 12 1 MECHANICAL DIMENSIONS BV1000GTV FIGURE 6 Mechanical dimension of the BV1000GTV...

Page 23: ...MADIC ITALIA Mod N Q060R06 23 26 12 2 PANEL DRILLING BV1000GTV FIGURE 7 Panel drilling of BV1000GTV...

Page 24: ...MADIC ITALIA Mod N Q060R06 24 26 12 3 FIXING INDICATIONS FOR BV1000GTV FIGURE 8 Panel Fixing for BV1000GTV Note Recommended fixing torque 0 6Nm...

Page 25: ...iance Where a forward or side reach is unobstructed the high reach shall be 48 inches 1220mm maximum and the low reach shall be 15 inches 380 mm minimum above the finish floor AFF or ground Operable p...

Page 26: ...f continued effort to improve the quality of its products and evidence published To this are constantly dedicated resources to ensure the accuracy of the information contained in the documents We will...

Reviews: