To prevent injury to the user or other people and property damage, the following instructions 
must be followed. Incorrect operation due to ignoring of instructions may cause harm or 
damage. The seriousness is classified by the following indications.

SAFETY PRECAUTIONS

This symbol indicates the possibility of death or serious injury.

Meanings of symbols used in this manual are as shown below.

!

!

WARNING

Always do this.

Never do this.

!

CAUTION

This symbol indicates the possibility of injury or damage to property.

Plug in power plug 
properly.

Do not modify power cord
length or share the outlet
with other appliances. 

Always ensure effective
earthing.

Unplug the unit if strange
sounds, smell, or smoke
comes from it.

Keep firearms away.

Ventilate room before operating air
conditioner if there is a gas leakage from
another appliance.

   Otherwise, it may cause electric
   shock or fire due to excess heat 
   generation.

  It may cause electric shock or 
  fire due to heat generation.

  Incorrect earthing may cause 
  electric shock.

  It may cause fire and electric
  shock.

  It may cause fire.

  It may cause explosion, fire and, burns.

  It may cause electric shock or fire
  due to heat generation.

  It may cause electric shock.

  It may cause failure of machine
  or electric shock.

  It may cause fire and electric 
  shock.

  It may cause fire and electric 
  shock.

  It may cause electric shock or fire.
  If the power cord is damaged, it 
  must be replaced by the manufac-
  turer or an authorised service 
  centre or a similarly qualified per-
  son in order to avoid a hazard.

  This could damage your health.

  Incorrect installation may cause 
  fire and electric shock.

  It may cause electric shock.

   It may cause an explosion or fire.

  It may cause failure and electric shock.

Do not operate or stop the
unit by inserting or pulling 
out the power plug.

Do not operate with wet
hands or in damp 
environment.

Do not allow water to run
into electric parts.

Do not use the socket if it is
loose or damaged.

Do not use the power cord
close to heating appliances.

Do not damage or use an 
unspecified power cord.

Do not direct airflow at 
room occupants only.

Always install circuit
breaker and a dedicated
power circuit.

Do not open the unit
during operation.

Do not use the power cord near 
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.

Do not disassemble or modify unit.

!

!

!

!

!

!

WARNING

!

2

!

!!

Summary of Contents for PACKAGED TERMINAL AIR CONDITIONER

Page 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference PACKAGED TERMINAL AIR CONDITIONER ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...r conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel onl...

Page 6: ...fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a sim...

Page 7: ...es food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techn...

Page 8: ...OTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is damaged it cannot be repaired it must be replaced with a cord from the Product Manufacturer Do not under any circumstances cut remove or bypass the grounding prong P...

Page 9: ...temperature is not too lower this function is off Automatic Quick Warm up for heat pump models only O O If the room temperature falls to 4 5 C 8 F below the set point temperature the reverse cycle heat is shut off and the electric strip heat is turned on for one cycle until heating is satisfied LED Indicators and Buttons The touch pad has buttons for MODE FAN POWER SETPOINT UP and SETPOINT DOWN It...

Page 10: ...with the compressor and electric heater NOTE The reverse cycle and electric heater can not be run at the same time FAN Fan operation only without heating and cooling UP DOWN BUTTONS Push the UP or DOWN button to increase or decrease the set temperature of the unit in cooling or heating mode The temperature can be set by O O increments of 1 C 1 F The setting temperature appears in the display NOTE ...

Page 11: ...2 CAUTION There are sharp edges that can cause serious cuts When lifting the air conditioner it is HEAVY Use 2 people to lift COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 20 Fig 2 PREPARATION OF SLEEVE ASSEMBLY optional Refer to the installation instruction of sleeve assembly for details UNIT INSTALLATION Carefully remove shipping tapes from the front panel See Fig 3 Fig 3 Shipping t...

Page 12: ...lange holes See Fig 7 and Fig 8 Reinstall front panel See Fig 9 Fig 7 Fig 8 1 2 Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into place 1 2 NOTE When vent control lever set at CLOSE only the air inside the room is circulated and filtered When set at OPEN some outdoor air will be drawn into room This will reduce heating or cooling efficiency CAUTION Do not put obstacles ar...

Page 13: ...aged it should be replaced immediately Operating without filters in place or with damaged filter will allow dirt and dust to reach indoor coil and reduce cooling heating airflow and efficiency of unit Airflow restriction may cause damage to unit UNIT DAMAGE HAZARD Keeping filters clean will Decrease cost of operation Save energy Prevent clogged indoor coil Reduce risk of premature component failur...

Page 14: ...n mode O O The unit may be set for C instead of F UNIT MAKING NOISES Clicking gurging and whooshing noises are normal during operation of unit WATER DRIPPING OUTSIDE If a drain kit has not been installed condensation runoff during very hot and humid weather is normal See Note 2 If a drain kit has been installed and is connected to a drain system check gaskets and fittings around drain for leaks an...

Page 15: ...2020001B0025 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...