background image

 

The air inlet, used for connecting air supply, has standard 1/4” NPT American Thread.

 

Line pressure should be increased to compensate for unusually long air hoses (over 25 feet). 
Minimum  hose  diameter  should  be  1/4”  I.D.  and  fittings  should  have  the  same  inside 
dimensions.

 

Operating Instructions 

For removal of frozen nuts, soak nuts in penetrating oil and break rust seal before removing 
with wrench. If nut does not start to move in three to five seconds, use a larger size  impact 
wrench. Do not use impact wrench beyond rated capacity as this will drastically reduce tool 
life.

 

To remove nuts, set the regulator to the maximum setting. To install nuts, set the regular to 
the minimum to medium setting. Do not over tighten the nuts.

 

WARNING

: Do not use hand tool sockets (chrome), use impact quality sockets only. Hand tool 

sockets can shatter and cause serious injury if used with air tools. Loose attachments, such as 
extension bars, can cause serious injury.

 

Maintenance 

Other factors outside the tool may cause loss of power or erratic action. Reduced Compressor 
output, excessive drain on the air line, moisture or restriction in air lines or the use of hose 
connections of improper size or poor condition may reduce air supply. Dirt or gum deposits in 
the tool may cut power. This may be corrected by cleaning the air strainer and flushing out 
the tool with gum solvent oil.    If outside conditions are in order and tool is out-of-warranty, 
clean,  reassemble,  and  re-lubricate,  or  take  tool  to  any  air  tool  service  center.  For  tools  in 
warranty period, send tool direct to Warranty Center.

 

 

Reviews: