background image

Instruction Manual

11

 

Outdoor Pedestal Drinking Fountain

CAUTION:  

The fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing

regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by

reason of connecting this product to supply line pressures lower than 20 PSI or higher than

105 PSI will void warranty.

START-UP

Initial water flow may have sputter due to air in the water lines; this will be eliminated

once air is purged from all water lines. Press and hold the push button until a steady

water stream is achieved.

STREAM HEIGHT ADJUSTMENT

To adjust the water stream height, insert a small flathead screwdriver through the access

hole in the center of the push button and turn the adjustment screw. Turn clockwise to raise

the stream height and counterclockwise to lower the stream height. For best adjustment,

the stream should be approximately 1-1/2" above the top of the bubbler, (see FIG.3).

FIG. 3

1 1/2''

•  Before freezing temperatures occur, turn off the water at the shut-off valve, disconnect

the water supply line tubing and blow out lines. Press down on push button to release any

air pressure that may remain in the lines.

•  Remove trap before winterization draining.

•  DO NOT allow water lines to freeze. Cracked or broken components due to freezing are

not covered by warranty.

DRAINING AND WINTERIZATION

Summary of Contents for 761223

Page 1: ...lace any part of this fountain unless it is specifically recommended in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce the risk of water damage Freezing Caution Before freezing temperatures occur refer to the Draining and Winterization section of this manual page 11...

Page 2: ...al 2 Outdoor Pedestal Drinking Fountain Package Contents Pedestal Bubbler Hardware Bag WWW GLOBALINDUSTRIAL COM SS316 SS316 GREEN SS316 BLACK SS316 BLUE DRAIN PAN DRAIN BUBBLER PUSH BUT TON BASE PEDESTAL COLOR OPTIONS ...

Page 3: ...r Mount Free Standing Product Dimensions 14 L x 14 W x 37 1 2 H Weight 58 5 lbs Installation Location Outdoor No of Stations 1 PART BREAKDOWN Instruction Manual 3 Safety Gloves 15 17mm Wrench Hammer Safety Glasses Adjustable Wrench Phillips Head Screwdriver Ref Qty Descrip on H1 1 Torx Key Wrench H2 1 Torx Drill Bit H3 4 Anchor Kit Small Flathead Screwdriver Outdoor Pedestal Drinking Fountain REQU...

Page 4: ...See Page 11 for Draining and Winterization Actual product configuration may vary based on model ordered Outdoor Pedestal Drinking Fountain 10 1 4 260mm 32 817mm 14 355mm 38 1 2 983mm 37 1 2 950mm FINISHED FLOOR ORIFICE HEIGHT 1 2 12mm HOLES 4 11 1 2 300mm 7 177mm 5 1 2 146mm B B 2 20 511mm 20 1 2 526mm 5 1 2 133mm 7 177mm 8 1 4 210mm INSIDE OPENING 8 1 4 210mm INSIDE OPENING ...

Page 5: ...tion of a trap on the water drain line may be necessary check local plumbing codes WARNING The fountain is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI Any damage caused by reason of connecting this product to supply line pressure higher than 105 PSI will void warranty To gain access to the drain and water line ...

Page 6: ...PEDESTAL TO GROUND Locate and install plumbing through ground as required Refer to Rough In Guide page 4 for proper location and correct plumbing This unit is designed to be installed on the surface of an existing or new concrete slab capable of supporting 400 lbs Position fountain base over plumbing and secure to ground using provided anchor kit H3 mounting hardware x4 H3 Anchor kit consists of 4...

Page 7: ...er internal water lines are preinstalled see below illustration for reference All water connections and drains must comply with local codes Install Shut off Valve Not Included Straight Flow Check Valve preinstalled Inlet Adapter preinstalled 3 8 O D Water Inlet preinstalled 3 8 O D Water Inlet preinstalled 1 4 O D Water Inlet preinstalled FRONT VIEW SIDE VIEW ...

Page 8: ...ION OF QUICK CONNECT FITTINGS NOTE WATERFLOW DIRECTION If drinking fountain is being installed in areas where cold temperatures may occur all water inlet lines are preinstalled with pipe insulation to help prevent freezing Installation of a trap on the water drain line may be necessary check local codes Always remove trap before winterization draining CAUTION Before freezing temperatures occur see...

Page 9: ...l other internal drain lines are preinstalled see below illustration for reference All water connections and drains must comply with local codes Installation of a trap on the water drain line may be necessary check local codes FRONT VIEW SIDE VIEW 32 3 4 Drain Tube Straight Drain Connector Confirm with local codes for trap and other drainage requirements ...

Page 10: ...e Drain Tube to the Drinking Fountain Drain Confirm with local codes for trap and other drainage requirements Note Turn on water supply and check all connections for leaks and proper operation Reinstall the 2 access panels using the 10 M6 x 10 flat head anti theft screws preciously removed from the fountain WARNING Flush all water supply lines thoroughly before initial use ...

Page 11: ...HEIGHT ADJUSTMENT To adjust the water stream height insert a small flathead screwdriver through the access hole in the center of the push button and turn the adjustment screw Turn clockwise to raise the stream height and counterclockwise to lower the stream height For best adjustment the stream should be approximately 1 1 2 above the top of the bubbler see FIG 3 FIG 3 1 1 2 Before freezing tempera...

Reviews: