Instruction Manual
11
Outdoor Pedestal Drinking Fountain
CAUTION:
The fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing
regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by
reason of connecting this product to supply line pressures lower than 20 PSI or higher than
105 PSI will void warranty.
START-UP
Initial water flow may have sputter due to air in the water lines; this will be eliminated
once air is purged from all water lines. Press and hold the push button until a steady
water stream is achieved.
STREAM HEIGHT ADJUSTMENT
To adjust the water stream height, insert a small flathead screwdriver through the access
hole in the center of the push button and turn the adjustment screw. Turn clockwise to raise
the stream height and counterclockwise to lower the stream height. For best adjustment,
the stream should be approximately 1-1/2" above the top of the bubbler, (see FIG.3).
FIG. 3
1 1/2''
• Before freezing temperatures occur, turn off the water at the shut-off valve, disconnect
the water supply line tubing and blow out lines. Press down on push button to release any
air pressure that may remain in the lines.
• Remove trap before winterization draining.
• DO NOT allow water lines to freeze. Cracked or broken components due to freezing are
not covered by warranty.
DRAINING AND WINTERIZATION