INSTALLATION INSTRUCTIONS

Vertical

window

Window Slider Kit 

Minimum:67.5cm(2.22ft).

Maxmum:123cm(4.04ft).

Window Slider Kit 

Minimum:67.5cm(2.22ft).

Maxmum:123cm(4.04ft).

Horizontal 

window

Fig.6

Fig.7

Location

The air conditioner should be placed on a firm 

foundation to minimize noise and vibration. For 

safe and secure positioning, place the unit on a 

smooth,level floor strong enough to support the unit.

The unit has casters to aid placement, but it should

only be rolled on smooth, flat surfaces. Use caution 

when rolling on carpet surfaces. Do not attempt to 

roll the unit over objects.

The unit must be placed within reach of a properly 

rated grounded socket.

Never place any obstacles around the air inlet or 

outlet of the unit.

Allow at least 30cm of space from the wall for 

efficient air-conditioning(see Fig.5).

     Your window slider kit has been designed to fit most 

     standard   Vertical and  horizontal window 

     applications,  However, it may be necessary for you to 

     improvise/modify some aspects of the installation 

     procedures for certain types of window. Please refer 

     to Fig. 6 & Fig.7 for minimum and maximum window 

     openings.Window slider kit can be fixed with a bolt

     (see Fig.7a).

Window kit Installation

     

Note:

 If the window opening is less than the mentioned 

     minimum length of the window slider  kit, cut the piece 

     with a hole in it shorter to fit for  the window opening. 

     Do never cut out the hole in window slider kit.  

INSTALLATION INSTRUCTIONS

9

Fig.5

bolt

Window slider kit

Fig.7a

  

1

11

3

/

''

4

5

  

1

11

3

/

''

4 5

Summary of Contents for 600506

Page 1: ...tain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please r...

Page 2: ......

Page 3: ...1 866 646 4332 MIDEA AMERICA CORPORATION PRODUCT REGISTRATION CENTER 11800 NW 100 ROAD STE 4 MEDLEY FL 33178 1037...

Page 4: ...or service at all Contact the authorised service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by yo...

Page 5: ...K Sociable remark 2 SAFETY PRECAUTIONS Safety rules 3 Operating condition 3 Electrical information 4 Accessories 4 Names of parts 5 Electronic control operating instructions 6 Operating instructions 7...

Page 6: ...free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least fre...

Page 7: ...ot remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Do not cover or obstruct the inlet...

Page 8: ...in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING Electrical Inform...

Page 9: ...t manually Carrying Handle both sides 1 2 3 Fig 1 Fig 2 Rear 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Wheel Air intake Drain Outlet Air intake Lower Air Filter Behind the grille 12...

Page 10: ...ng NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds...

Page 11: ...5 seconds and the system will autom atically revert back to display the previous temperature setting Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto S...

Page 12: ...30 minutes The set temperature will then increase O O cooling or decrease heating by another 1 C 2 F after an additional 30 minutes This new temper ature will be maintained for 7 hours before it retu...

Page 13: ...ded socket Never place any obstacles around the air inlet or outlet of the unit Allow at least 30cm of space from the wall for efficient air conditioning see Fig 5 Your window slider kit has been desi...

Page 14: ...e adjustable window kit if the width of window is less than 27 inches Open the window sash and place the window slider kit on the foam seal B Fig 9 3 Cut the foam seal adhesive type to the proper leng...

Page 15: ...width of window is less than 27 inches Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the...

Page 16: ...it installation 2 Push the Exhaust hose into the air outlet opening along the the arrow direction See Fig 18 IMPORTANT DO NOT OVER BEND THE DUCT SEE Fig 20 12 Fig 17 Fig 18 Fig 20 The exhaust hose can...

Page 17: ...tight and do not let the water leak When the water level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water dra...

Page 18: ...pating along the arrow direction see Fig 25 and install the lower filter along the arrow direction see Fig 25 2 Unit enclosure Use a lint free cloth soaked with neutral detergent to clean the unit enc...

Page 19: ...e are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Place the unit on a flat level ground if...

Page 20: ...INDUSTRIAL GLOBAL INDUSTRIAL GLOBAL INDUSTRIAL GLOBAL INDUSTRIAL GLOBAL Midea Midea Midea 1 866 646 4332...

Reviews: