STANDARD EQUIPMENT
The control panel and booster are mounted on the top of the chamber. There are
three operational control switches housed in the control panel : POWER
(ON
-OFF
); MOTOR
(START
-STOP
);and TIMER
(MANUAL
-AUTO
).
Mechanical thermostat for wash is located outside the tank, rinse thermostats are
located inside the control panel. Suggested temperature range for wash is 55-65
℃
,
and final rinse is 82-95
℃
.
Motor and Pump Units
The 2 horse power wash pump and motor are centrifugal-type cast stainless steel
with stainless steel impeller.
Motor is available in the following voltages:
Volts
Hz
Phase
380
50
3
The conveyor motor is a 0.22 Kw gear motor with the same voltage as the wash
pump motor with built-in overloaded protection system.
Clutch/Rack Transport Protection
The conveyor motor transfers power to the rack transport system through the clutch.
When the machine is overloaded or the racks jam the clutch sends a signal to stop
the conveyor motor to protect the machine, rack transport mechanism and motor.
Heater Protection
A float switch located in the wash tank automatically turns off the heat supply if the
water level is too low. Once the water returns to a required level, the heating circuit
becomes operational if heat is demanded.
An over-heat protector is also provided for electric heat. If overheating occurred, the
heat supply will be turned off . Turn the POWER switch OFF and contact your
authorized service office.