Global PCS SS0001 User Manual Download Page 12

Global PCS Inc.   

SS0001 User Guide 

ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ

 

Dec.  10, 2002       Global PCS Inc., Proprietary and Confidential       Page  12 of  18 

 

3.2 Other function of SS0001 

 

SS0001 LAP provides a COM port interface, you must have a RS-232 line to connect between 

SS0001 and DT (Data Terminal). After DT creates a connection with COM port (usually using 

windows HyperTerminal), it can send some commands to control SS0001 through the created 

COM port. Note that the COM port settings are non-parity check, data bit is 8, 1 stop bit, and 

baudrate  is 57600 bps with hardware flow control off. 

 

 

 

   

 

 

 

Figure 3.11 SS0001 Function Display 

 

Summary of Contents for SS0001

Page 1: ...uide Version 1 1 2 December 12 2002 Document Number BTAP UM 0001 Global PCS Inc 1 Innovation Road II Hsinchu Science Based Industrial Park Hsinchu 300 Taiwan R O C Phone 886 35771155 Fax 886 35772578...

Page 2: ...cess to Internet by xDSL modem and Cable modem n Access to Local Area Network by Ethernet port RJ45 n LAN Access point to point operation to provide Local Area Networking n High performance antenna n...

Page 3: ...Global PCS Inc SS0001 User Guide Dec 10 2002 Global PCS Inc Proprietary and Confidential Page 3 of 18 2 Install Hardware l Global PCS Bluetooth Access Point x1 l 6V Power Adapter x 1...

Page 4: ...et Explorer and key in http 1 1 1 1 5000 or the physical Access Point IP address http xxx xxx xxx xxx 5000 to connect to web server II Using any PC in Internet and key in the physical Access Point IP...

Page 5: ...word network type selection Fixed IP address DHCP or PPPoE security level selection enable data encryption or not Figure 3 2 shows the description above Figure 3 2 Access Point Description 3 1 Changep...

Page 6: ...Global PCS Inc SS0001 User Guide Dec 10 2002 Global PCS Inc Proprietary and Confidential Page 6 of 18 Figure 3 3 Change Password Figure 3 4 Change Password Complete...

Page 7: ...level 3 and if you select level 3 you must enter the PIN code You also can enable data encryption or not Figure 3 5 Configuration Note Bluetooth Security level Level 1 Non secure a device will not in...

Page 8: ...If you select fixed IP address they will show the IP setting screen You may key in the network setting information such as the IP address Subnet mask Gateway address and DNS address in Figure 3 6 Fig...

Page 9: ...prietary and Confidential Page 9 of 18 Figure 3 7 Network Configuration Complete fixed IP address 3 2 2 Network configuration PPPoE If you select PPPoE you must input the PPPoE login ID and password F...

Page 10: ...Global PCS Inc SS0001 User Guide Dec 10 2002 Global PCS Inc Proprietary and Confidential Page 10 of 18 Figure 3 8 Network configuration PPPoE Figure 3 9 Network configuration Complete PPPoE...

Page 11: ...Guide Dec 10 2002 Global PCS Inc Proprietary and Confidential Page 11 of 18 3 2 2 Network configuration DHCP The configuration of DHCP is very easy Figure 3 10 shows the result Figure 3 10 Network co...

Page 12: ...a RS 232 line to connect between SS0001 and DT Data Terminal After DT creates a connection with COM port usually using windows HyperTerminal it can send some commands to control SS0001 through the cr...

Page 13: ...al Page 13 of 18 o Open the server port Open the server serial port for RFCOMM connection All ports are opened by default for 7 connections c Close the port Close the server serial port for RFCOMM con...

Page 14: ...2 Global PCS Inc Proprietary and Confidential Page 14 of 18 m Change LAP mode Change LAP mode among general accessible mode limit accessible mode non accessible mode and connectable mode only r Change...

Page 15: ...tial Page 15 of 18 w Watchdog test Check watchdog and to see if it works a Change display mode Display debug message on hyper terminal or not h ExecuteHCIcommand Enter an HCI command to execute s Enab...

Page 16: ...Inc SS0001 User Guide Dec 10 2002 Global PCS Inc Proprietary and Confidential Page 16 of 18 p Halt the PPP server Stop the PPP service PPP now is not available s Shutdown PPP Close all existing PPP c...

Page 17: ...d found to comply with the limits for a Class B Digital Device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residen...

Page 18: ...8 of 18 Importance Note To comply with FCC RF exposure compliance requirements the antenna used for this transmitter must be installed to provide a separation distance of at least 20cm from all person...

Reviews: