Global Invacom FibreIRS dSCR GTU Technical Supplement Download Page 3

The purpose of this guide is to enable the successful installation of 
the dSCR GTU as part of a Global Invacom FibreIRS Installation. 

This guide assumes that:

 

• 

The GTU will be connected to a suitable Global Invacom FibreIRS 
Passive Optical Network (PON), providing minimum optical signal 
levels of -12.2dBm* at the connection point of the GTU. 

• 

The GTU will be been installed in a dry indoor environment and 
mounted vertically with suitable fixings. 

• 

The installation will be carried out by a competent person.

 

 

• 

All ferrule end faces of the FC/PC optical connectors are cleaned 
prior to making a connection using a suitable fibre optic cleaning 
kit. 

• 

The installer has followed the installation guide for the ODU32 or 
optical LNB. 

* Based upon launch output of +7dBm

 

Cable and Connections 

• 

Cables used should be industry approved coaxial cable and should 
be terminated using an F type connector. 

• 

Fibre optic cable should be Global Invacom approved single mode 
with FC/PC connections. 

dSCR GTU (D000199)

 

Technical Supplement

 

Introduction

 

 

   

When pulling pre-terminated fibre cables please ensure the connector  
is well protected, and that no force is applied to the end connector. 

Reviews: