The purpose of this guide is to enable the successful installation of
the dSCR GTU as part of a Global Invacom FibreIRS Installation.
This guide assumes that:
•
The GTU will be connected to a suitable Global Invacom FibreIRS
Passive Optical Network (PON), providing minimum optical signal
levels of -12.2dBm* at the connection point of the GTU.
•
The GTU will be been installed in a dry indoor environment and
mounted vertically with suitable fixings.
•
The installation will be carried out by a competent person.
•
All ferrule end faces of the FC/PC optical connectors are cleaned
prior to making a connection using a suitable fibre optic cleaning
kit.
•
The installer has followed the installation guide for the ODU32 or
optical LNB.
* Based upon launch output of +7dBm
Cable and Connections
•
Cables used should be industry approved coaxial cable and should
be terminated using an F type connector.
•
Fibre optic cable should be Global Invacom approved single mode
with FC/PC connections.
dSCR GTU (D000199)
Technical Supplement
Introduction
•
When pulling pre-terminated fibre cables please ensure the connector
is well protected, and that no force is applied to the end connector.