background image

 

1

Wall Mounted Filtered Water Cooler

052120

globalindustrial.ca

User's manual

Manual del usuario

Manuel de l'utilisateur

Customer Service

US: 1-800-645-2986

Servicio de atención al Cliente

US: 1-800-645-2986

Service à la clientèle

Canada: 888-645-2986

        WARNING

  

 Keep compressor in upright position for 24 hours 

before water connections and initial power-on. Failure 

to do so will void warranty.

• For indoor commercial use only.

•  All installation work must be performed by authorized 

service personnel.

•  Two or more people are recommended to lift and install 

the unit.

•  To avoid the risk of property damage and/or personal 

injury, mount the unit to a flat finished wall surface with 

adequate support.

•  

Check local codes for plumbing requirements prior  

to installation.

•  Prior to initial installation, install a shut-off valve (not 

included) from the water supply.

•  Thoroughly flush all water lines and fittings of all foreign 

matter before connecting to the cooler. Failure to do so 

will void warranty.

• Check for any leaks before initial operation.

•  DO NOT attempt to repair or replace any part of your 

appliance unless it is specifically recommended in 

this manual. All other services should be referred to a 

qualified technician. 

• For use with clean, clear potable drinking water only.

•  Shut-off water supply during installation to reduce risk 

of water damage. 

•  

Ensure proper ventilation by allowing appropriate 

clearance of housing louvers to the wall on each side 

of the cooler, as specified in rough-in guide.

•  NEVER wire the compressor directly to an electrical supply.

• DO NOT allow children to play with the appliance.

•  Interior of unit may contain sharp edges. Wear gloves 

when handling or servicing unit.

•  Failure to follow installation instructions will void warranty.

Note:

 These fixtures are intended for indoor commercial 

use only. Do not expose to freezing temperatures. 

The grounding of electrical equipment to water lines is 

a common procedure. This grounding may be in the 

building or occur away from the building. This grounding 

can cause electric feedback into the water cooler 

creating an electrolysis which creates a metallic taste or 

causes the water metal content to increase. Connect to 

water supply using non-conductive materials.

Model 761217

Read this manual thoroughly prior to 

installation, operation or maintenance. 

Keep these instructions in a safe location 

for future reference. For questions, visit 

globalindustrial.com or contact Customer 

Service at 1-800-645-2982.

Summary of Contents for 761217

Page 1: ...in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water d...

Page 2: ...7 Pencil 8 Level Device 9 8 75 lb Capacity Flat Head Wall Anchors appropriate for your wall type 10 8 Flat Head Anchor Screws WARNING Review manual thoroughly and verify rough ins before installation...

Page 3: ...3 User s Manual Wall Mounted Filtered Water Cooler Check local codes for plumbing requirements prior to installation...

Page 4: ...Filler Access Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the...

Page 5: ...blue Activation Connectors B to the Solenoid Valve B Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the Stainless Steel Pan on top o...

Page 6: ...e wall using appropriate anchors 4 5 CAUTION Hanging assembled unit to wall Carefully hang assembled unit onto the wall by lowering onto mounting bracket WARNING installation of equipment should be pe...

Page 7: ...on button Connect the Reset Button connection cable to the Activation Buttons located at the top of the filter access door frame Reinstall the filter access door using the provided key Unit is now rea...

Page 8: ...Lower Cover and access the thermostat onthefronthousingframe Usingaflatheadscrewdriver turn thermostat screw clockwise to lower temperature setting Note Please allow 5 10 minutes for water temperature...

Page 9: ...s will be displayed Tap SET button 3 times to select 1500 gallon filter option 2 LED lights will be displayed Tap SET button 4 times to select NO filter option 1 LED lights will be displayed 3 Tap ENT...

Page 10: ...water drain Note Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties Maintenance Issue Possible Cause Suggested Action Water Temperature not Cool The ther...

Reviews: